IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Akademik Gastroenteroloji Dergisi
  • Volume:22 Issue:1
  • Endoscopic Ultrasound-guided Fine Needle Aspiration for Benign Liver Diseases: Single-center Experie...

Endoscopic Ultrasound-guided Fine Needle Aspiration for Benign Liver Diseases: Single-center Experience

Authors : Salih TOKMAK, Sinem Coşkun KANTARCIOĞLU, Serkan TORUN
Pages : 1-5
Doi:10.17941/agd.1255462
View : 34 | Download : 9
Publication Date : 2023-04-30
Article Type : Research Paper
Abstract :Background and Aim: To report the efficacy and safety results of our initial experience with the endoscopic ultrasound-guided liver biopsy insert ignore into journalissuearticles values(EUS-LB);. Materials and Method: Retrospective analysis of a prospectively maintained database in a tertiary care referral center. Consecutive patients who had EUS-LB for benign parenchymal diseases, using a 19 gauge fine needle with single-pass, three actuations, and wet suction technique between June 2022 and December 2022 were included. Patient demographics, procedure-related parameters, and the quality of specimens were investigated Results: The technical success was 100%. Of the 16 patients, four had a second procedure due to inadequate sampling. The median total sample length, the median number of pieces and the median length of the longest piece in fragmented samples, and the median number of complete portal tracts were 11mm insert ignore into journalissuearticles values(range, 0.2-2.5);, 9.6 insert ignore into journalissuearticles values(range 0-20);, 0.2mm insert ignore into journalissuearticles values(range 0.2-1.5); and 3.5 insert ignore into journalissuearticles values(range 0-19); respectively. None of the patients had any adverse events following the procedure. Conclusion: EUS-LB may be an alternative to other liver biopsy procedures but further studies are needed to determine the ideal needle type and technique.
Keywords : endoskopik ultrasonografi, ince iğne aspirasyon biyopsisi, karaciğer hastalıkları

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026