IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Kocatepe Tıp Dergisi
  • Volume:16 Issue:2
  • Santral Kornea Kalınlığının Ölçümünde Scheimpflug Fotoğraflama, Optik Kohorens Tomografi ve Ultrason...

Santral Kornea Kalınlığının Ölçümünde Scheimpflug Fotoğraflama, Optik Kohorens Tomografi ve Ultrasonik Pakimetri Yöntemlerinin Karşılaştırılması

Authors : Mustafa DOĞAN, Nurgül AVCI, Mehmet DURMAZ, Fatih KARTAL, Mehmet AKAY, Sibel İNAN
Pages : 132-135
Doi:10.18229/ktd.22397
View : 18 | Download : 8
Publication Date : 2015-07-15
Article Type : Other Papers
Abstract :Amaç : Santral kornea kalınlığının(SKK) ölçümünde ultrasonik pakimetri(UP), Scheimpflug fotograflama(SF) ve optik kohorens tomografi(OKT) yöntemleri ile elde edilen değerlerin karşılaştırılması. Gereç ve Yöntem : 43 sağlıklı genç erişkinin sağ ve sol göz (toplam 86 göz) santral korneal kalınlığı UP, SF ve OKT yöntemleri ile ölçüldü. Santral kornea kalınlığı, yaş, cinsiyet, göz içi basıncı ve otorefraktokeratometre değerleri kaydedildi. Elde edilen değerler karşılaştırıldı. Bulgular : Ortalama yaş 21,35 ± 0,75 (20-24) idi. UP ile ölçülen ortalama SKK sağ göz için 558,42 ± 38,87 (477-620) mikron, sol göz için 556,84 ± 39,83 (477-641) mikron idi.SF ile ölçülen ortalama SKK sağ göz için 555,02 ± 37,90 (486-631) mikron, sol göz için 550,44 ± 42,30 (453-630) mikron idi.OKT ile ölçülen ortalama SKK sağ göz için 563, 52 ± 38,52 (492-644) mikron, sol göz için 563,72 ± 39,84(482-644) mikron idi.Her üç yöntem ile ölçülen değerler karşılatırıldığında UP ve SF ile elde edilen değerler arasında istatistiki olarak anlamlı fark saptanmaz iken OKT ile elde edilen değerler ile arasında UP(P<0.003) ve SF(P<0.001) ile elde edilen değerler arasında istatistiki olarak anlamlı fark tespit edildi. OKT ile elde edilen değerler daha yüksek bulundu (yaklaşık 7 mikron). Sonuç : Yapılan SKK ölçümünde UP ve SF ile elde edilen değerler birbirleri ile uyumludur. OKT ile elde edilen değerler daha yüksektir. Günlük uygulamada bu durum dikkate alınmalıdır.       Detect languageAfrikaansAlbanianArabicArmenianAzerbaijaniBasqueBelarusianBengaliBosnianBulgarianCatalanCebuanoChichewaChinese (Simplified)Chinese (Traditional)CroatianCzechDanishDutchEnglishEsperantoEstonianFilipinoFinnishFrenchGalicianGeorgianGermanGreekGujaratiHaitian CreoleHausaHebrewHindiHmongHungarianIcelandicIgboIndonesianIrishItalianJapaneseJavaneseKannadaKazakhKhmerKoreanLaoLatinLatvianLithuanianMacedonianMalagasyMalayMalayalamMalteseMaoriMarathiMongolianMyanmar (Burmese)NepaliNorwegianPersianPolishPortuguesePunjabiRomanianRussianSerbianSesothoSinhalaSlovakSlovenianSomaliSpanishSundaneseSwahiliSwedishTajikTamilTeluguThaiTurkishUkrainianUrduUzbekVietnameseWelshYiddishYorubaZulu   AfrikaansAlbanianArabicArmenianAzerbaijaniBasqueBelarusianBengaliBosnianBulgarianCatalanCebuanoChichewaChinese (Simplified)Chinese (Traditional)CroatianCzechDanishDutchEnglishEsperantoEstonianFilipinoFinnishFrenchGalicianGeorgianGermanGreekGujaratiHaitian CreoleHausaHebrewHindiHmongHungarianIcelandicIgboIndonesianIrishItalianJapaneseJavaneseKannadaKazakhKhmerKoreanLaoLatinLatvianLithuanianMacedonianMalagasyMalayMalayalamMalteseMaoriMarathiMongolianMyanmar (Burmese)NepaliNorwegianPersianPolishPortuguesePunjabiRomanianRussianSerbianSesothoSinhalaSlovakSlovenianSomaliSpanishSundaneseSwahiliSwedishTajikTamilTeluguThaiTurkishUkrainianUrduUzbekVietnameseWelshYiddishYorubaZulu                   Text-to-speech function is limited to 100 characters   Options : History : Help : Feedback
Keywords : Santral kornea kalınlığı, ultrasonik pakimetri, Scheimpflug fotograflama, optik kohorens tomografi

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025