IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Konya Mühendislik Bilimleri Dergisi
  • Volume:12 Issue:3
  • SYNTHESIS of P(N-ISOPROPYL ACRYLAMIDE - HYDROXYPROPYL METHACRYLATE) THERMO RESPONSIVE COPOLYMER FILM...

SYNTHESIS of P(N-ISOPROPYL ACRYLAMIDE - HYDROXYPROPYL METHACRYLATE) THERMO RESPONSIVE COPOLYMER FILMs BY INITIATED CHEMICAL VAPOR DEPOSITION METHOD

Authors : Emine Sevgili Mercan, Kurtuluş Yılmaz, Mustafa Karaman
Pages : 687-699
Doi:10.36306/konjes.1408922
View : 60 | Download : 35
Publication Date : 2024-09-01
Article Type : Research Paper
Abstract :This study illustrates the deposition of thermo responsive p(N-isopropyl acrylamide-hydroxypropyl methacrylate) p(NIPAAm-HPMA) copolymer thin films by initiated chemical vapor deposition (iCVD) method using tert-butyl peroxide (TBPO) as the initiator. Copolymers were deposited at three different HPMA flow rates and the effects of NIPAAm/HPMA flow rate ratio on the deposition rate, structure and responsive properties of the as-deposited films were investigated. The highest deposition rate of 50 nm/min was observed for the copolymer deposited using lowest NIPAAm/HPMA monomer ratio studied. The deposition rate showed a significant increase with decreasing NIPAAm/HPMA flow ratio. Results of FTIR and XPS spectroscopy analyses revealed a significant preservation of structural retention in iCVD p(NIPAAm-HPMA) thermo-responsive films. Lower critical solution temperatures (LCST) of p(NIPAAm-HPMA) films were determined by carrying out a temperature-dependent contact angle analysis. Accordingly, it was shown that LCST was varied between 19 and 23 oC, which was observed to be dependent on the NIPAAm/HPMA monomer ratio. That LCST range is considerably below the literature- reported values for pNIPAAM, which makes the as-deposited copolymer suitable for applications that require thermos-responsive properties at lower temperatures.
Keywords : Thermo responsive, iCVD, LCST, Polymeric Thin Film, Hydrogel

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025