IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Lalahan Hayvancılık Araştırma Enstitüsü Dergisi
  • Volume:58 Issue:2
  • Comparison of Two Methods Using Measurement of the Surface Area of M. Longissimus Dorsi (MLD)*

Comparison of Two Methods Using Measurement of the Surface Area of M. Longissimus Dorsi (MLD)*

Authors : Aykut Asım AKBAŞ, Mehmet SARI, Özkan ELMAZ, Mustafa SAATCI
Pages : 77-80
View : 16 | Download : 8
Publication Date : 2018-12-27
Article Type : Research Paper
Abstract :The purpose of study was to compare two different methods to measure the M. longissimus dorsi (MLD) surface area. For this aim, planimeter method and a new method with Autocad software programme were evaluated. MLD areas from 47 samples from Hemşin and Tuj breeds and 63 samples from Saanen, Honamlı and Hair breeds were used. In planimeter method, traced MLD area by hand to acetate paper transferred into squared centimetres. In the new procedure, the surface area of the MLD was traced onto acetate papers and then transferred to a computer by scanning. The AutoCAD software program was used to calculate the area of the MLD. Statistically significant (P< 0.001) correlation coefficients between two methods were detected as 0.999 and 0.998 for Hemsin and Tuj lambs and 0.996, 0.988 and 0.994 for Saanen, Hair and Honamlı kids, respectively. Correlation coefficiant of whole data was 0.995. In the study, there was also found that, time savings can be considered as a notable factor for Autocad method (134.45 second) than the planimeter metod (255.70 second) (P< 0.001). According to findings, the Autocad method can be used as a time saving practical usage instead of planimeter method. Also, this technique can be combined with the some image capturing methods, to reach the reliable results in a short time. 
Keywords : Autocad, Musculus longissimus dorsi, planimeter

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025