  • PERFORMANCE IMPROVEMENT IN A 1 MW GRID-CONNECTED PV POWER PLANT INSTALLED IN YATAĞAN-MUĞLA TURKEY VI...

PERFORMANCE IMPROVEMENT IN A 1 MW GRID-CONNECTED PV POWER PLANT INSTALLED IN YATAĞAN-MUĞLA TURKEY VIA STATCOM ON MATLAB-Simulink PORTAL

Authors : Altan KALAY, Ali AĞÇAL, Koray ULGEN
Pages : 113-125
Doi:10.21923/jesd.1168233
View : 18 | Download : 10
Publication Date : 2023-03-27
Article Type : Research Paper
Abstract :A grid-connected power system\`s performance depends on the produced energy\`s power quality and power coefficient. The higher the power quality of the energy transferred to the grid, the more critical it is for power plants, energy distribution systems and end-users. This study investigated the optimisation possibilities obtained by applying STATCOM insert ignore into journalissuearticles values(Static VAR Compensation); for a 1 MW PV-based Solar Power Plant insert ignore into journalissuearticles values(PV-SPP); in the Muğla-Türkiye province. First, the data of components such as the inverter and PV panel that make up the plant were obtained, and the raw MATLAB-Simulink modelling of the plant was carried out. System performance outputs were obtained by adding STATCOM modelling to the obtained modelling. The scientific results of the optimisation would be obtained if this technique was applied to the existing power plant. Since STATCOM also performs the RPC insert ignore into journalissuearticles values(Reactive Power Compensation); process, it is an up-to-date and effective technique that improves system energy power quality. According to the simulation results, this system with STATCOM draws 24,043% and 11,671% less reactive power and current than the non-STATCOM system.
Keywords : MATLAB Simulink, PV GES, STATCOM, Reaktif Güç Kompanzasyonu, PV Sistemler

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.