IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Politeknik Dergisi
  • Volume:22 Issue:1
  • Experimental Study of Thermal Performance and Pressure Differences of Different Working Fluids in Tw...

Experimental Study of Thermal Performance and Pressure Differences of Different Working Fluids in Two-phase Closed Thermosyphons Using Solar Energy

Authors : Engin ÖZBAŞ
Pages : 121-128
Doi:10.2339/politeknik.407258
View : 35 | Download : 7
Publication Date : 2019-03-01
Article Type : Research Paper
Abstract :An experimental study is carried out to investigate the pressure distribution and thermal performance of gravity assisted heat pipe charged with different working fluids. Methanol, water and Mono-Ethylene-Glycol insert ignore into journalissuearticles values(MEG); are chosen as working fluids which have different boiling point, density and viscosity. An experimental test apparatus is designed and produced including three heat pipes that heat input on the evaporator section are provided by solar energy. Measurements are conducted on the heat pipe surface for pressure and temperature variations. Pure antifreeze is chosen as working fluid, due to its high boiling point, along with water and methanol which are widely used in thermosyphon type heat pipes. Heat pipes are put into parabolic focused vacuumed glass tube and operated by solar energy for 11 days in order to achieve high temperatures. Data taken from 06.30 to 18.30 is taken into consideration for experimental results. Experimental results are evaluated for two days as insert ignore into journalissuearticles values(i); sunny and insert ignore into journalissuearticles values(ii); cloudy days by choosing days with the highest and lowest solar radiation.  insert ignore into journalissuearticles values(i); As for the sunny day, the highest storage water temperatures for methanol, water and antifreeze were 90.0°C, 83.5°C and 86.7°C and the pressure values were 6.7 bar, 1.6 bar and 1.9 bar respectively. insert ignore into journalissuearticles values(ii); And for the cloudy day, the respective values of temperature and pressure were measured as; 43.9°C, 39.3°C, 29.0°C, and 2.0 bar, 0.2 bar and -0.3 bar.
Keywords : Heat pipe, solar energy, heating, performance

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026