IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Politeknik Dergisi
  • Volume:26 Issue:2
  • Effects of Slab Types on the Seismic Behavior and Construction Cost of RC Buildings

Effects of Slab Types on the Seismic Behavior and Construction Cost of RC Buildings

Authors : Gökhan TUNÇ, Abdul Basir AZİZİ, Tuğrul TANFENER
Pages : 553-567
Doi:10.2339/politeknik.971343
View : 1255 | Download : 2131
Publication Date : 2023-07-05
Article Type : Research Paper
Abstract :Reinforced concrete-framed buildings are commonly preferred to other types of buildings in Turkey. In these types of buildings, a two-way slab with beams, flat, waffle, and ribbed slab types are widely used. In building design, determining the best slab type that will perform well under gravity and lateral loads, with the least cost, is required. However, the proper selection of slab type has generally been overlooked by designers due to the emphasis on other structural members, such as beams, columns and structural walls. For this reason, the structural contribution of floors to building design has not been adequately examined. This shortcoming must be inspected in detail starting from the very first step of the design stage of a building. This study assesses the effects of different slab types on multi-story reinforced concrete buildings by investigating their structural behaviors while trying to optimize their overall cost. For this purpose, a total of 36 structural models were constructed, analyzed, and designed according to the current Turkish Building Codes and Standards. The type of slab system insert ignore into journalissuearticles values(a two-way slab with beams, flat, waffle and ribbed);, the number of floors insert ignore into journalissuearticles values(10, 20 and 30);, and span length insert ignore into journalissuearticles values(6, 7.5, and 9 m); were selected as the key parameters in these analyses. The buildings were assumed to be office buildings located in a seismically-active zone in Istanbul. The results indicated that a two-way slab with beams was the most economical slab type for 6-meter spans, while the waffle slab was the most economical for spans larger than 7.5 meters. Based on these results, the flat slab was found to be the most expensive slab type in all cases. Out of all slab types, the two-way slab with beams exhibited better earthquake performance, while the waffle and flat slabs provided relatively poor earthquake performances.  
Keywords : Çok katlı binalar, deprem davranışı, döşeme türleri, betonarme binalar

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026