IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Dergisi
  • Volume:8 Issue:2
  • Radyoterapi Işınlarının Kalite Kontrolünde Yarı İletken Diyot ve Silindirik İyon Odası Performanslar...

Radyoterapi Işınlarının Kalite Kontrolünde Yarı İletken Diyot ve Silindirik İyon Odası Performanslarının Karşılaştırılması

Authors : Serkan Okay, Bayram Demir, Asuman Öztaş
Pages : 151-162
View : 38 | Download : 17
Publication Date : 2013-12-05
Article Type : Research Paper
Abstract :Bu çalışmada; 6 ve 18 MV foton ışınları kullanılarak yarı iletken diyotlar ve silindirik iyon odalarının su fantomunu performansları incelenmiştir. Bu amaçla, yüzde derin doz ve doz profillerinden elde edilen çeşitli veriler bir birleri ile karşılaştırıldı. De_erler arasındaki farklar genel olarak limitler içinde tespit edilmiştir. Çalışmanın sonucunda diyot ve iyon odası tipindeki detektörlerin her ikisinin de su fantomu ile yapılan rutin ölçümlerde kullanılabileceği görülmüştür. Fakat detektör yapılarının tamamen farklı oluşu sebebiyle aralarında bazı dozimetrik farklar mevcuttur. Bu farklar gözetilerek detektör kullanımları arasında tercih yapılabilir. Anahtar kelimeler: Diyot, iyon odası, radyoterapi, dozimetri A Comparison for the Performances of Semiconductor Diodes and Cylindrical Ion Chambers in the Quality Control of Radiotherapy Beams Abstract: In present study, water phantom performances of using 6 and 18 MV photon beams were investigated. For this purpose, several data obtained form percent depth dose graphics and dose profiles were compared to each other. It was determined that the differences between the values were generally found within the limits. In the end of study, it was seen that semiconductor diodes and cylindrical ion chambers can be used interchangeably. But, there are some dozimetric differences between both detectors because of different detector structures. Choice of the detector can be made by taking into account these differences. Key words: Diode, ion chamber, radiotherapy, dosimetry
Keywords : Diyot, iyon odası, radyoterapi, dozimetri

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026