IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Uluslararası Bilim Teknoloji ve Tasarım Dergisi
  • Volume:3 Issue:1
  • Investigation of Size Exclusion Chromatography (SEC) Column Performance for Detection of Microplasti...

Investigation of Size Exclusion Chromatography (SEC) Column Performance for Detection of Microplastics in Aquatic Environment

Authors : Belgın IZGI, Büşra KURUCA
Pages : 99-112
View : 55 | Download : 7
Publication Date : 2022-06-30
Article Type : Research Paper
Abstract :Microplastics have become a problem of the modern era with the increasing use of plastics. However, the effects of microplastics on living beings are not known exactly. As stated in the booklet `Microplastics in Drinking Water` published by the World Health Organization insert ignore into journalissuearticles values(WHO); in 2019, there is no standard method for the detection of microplastics. Although there are various analysis methods for the determination of microplastics in the literature, some deficiencies are observed. In this study, it is aimed to analyze the microplastics in aquatic environment without using organic solvents, especially in accordance with green chemistry. In this context, Size Exclusion Chromatography was used and the performance of four different Ultra-hydrogel columns suitable for aqueous mobile phases was tested. Polyethylene glycol insert ignore into journalissuearticles values(PEG); standards with different molecular masses were used during this performance test. As a result of the study, the theoretical plate numbers of Ultra-hydrogel 250 Å, Ultra-hydrogel 500 Å, and Ultra-hydrogel 1000 Å columns were calculated as 256, 713, and 342, respectively, and the regression coefficients insert ignore into journalissuearticles values(R2); were calculated as >0.97. The theoretical plate number of Ultra-hydrogel 2000 Å column was not calculated because of lower regression coefficient.
Keywords : Microplastics, Size Exclusion Chromatography, Ultra hydrogel Columns

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026