IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Black Sea Journal of Engineering and Science
  • Cilt: 8 Sayı: 4
  • Development and Validation of a Simple HPLC-UV Method for Analysis of Harmine

Development and Validation of a Simple HPLC-UV Method for Analysis of Harmine

Authors : Galip Mesut Demir, Afife Büşra Uğur Kaplan, Mine Gülaboğlu, Meltem Çetin
Pages : 1096-1102
View : 58 | Download : 60
Publication Date : 2025-07-15
Article Type : Research Paper
Abstract :In this study, a rapid, simple, and sensitive HPLC-UV method was developed and validated in accordance with ICH Q2 (R1) guideline for the quantitative analysis of harmine (HRM), a main β-carboline alkaloid found in the Peganum harmala (Uzerlik) plant. The method was established based on the UV spectral analysis, which indicated maximum absorbance for HRM at 243 nm. A mixture of methanol and ultrapure water containing 1% formic acid (50:50, v/v) was selected as the mobile phase. In the separation carried out under isocratic conditions, the retention time of HRM was determined as 5.5 min, and the entire analysis was completed in under 8 min. The method demonstrated excellent linearity within the concentration range of 1–36 µg/mL, with a correlation coefficient (R²) of 0.99998. The accuracy and precision parameters of the method were found to be within acceptable limits, with relative error (RE) and relative standard deviation (RSD%) both below 2. The limits of detection and quantification (LOD and LOQ) were 0.269 µg/mL and 0.816 µg/mL, respectively. Also, it was determined that HRM standard solutions were stable for up to 7 days when stored at different temperatures (−20°C, 2–8°C, 25°C). In conclusion, this method offers a reliable alternative for the quantitative determination of HRM with high analytical quality, reproducibility, and short time. It can be widely used in routine laboratory practices for the monitoring of HRM in pure form and in various pharmaceutical formulations.
Keywords : Harmine, HPLC-UV method, Peganum harmala, Stability, Validation

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026