IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • European Journal of Research in Dentistry
  • Volume:7 Issue:3
  • The Effect of Cavity Disinfectant on Microleakage of Self-adhesive Composite Restorations in Class V...

The Effect of Cavity Disinfectant on Microleakage of Self-adhesive Composite Restorations in Class V Cavities

Authors : Bengü Doğu, Ezgi Acar, Nına Farshidian, Gülçin Bilgin Göçmen, Bilge Tarçin, Pınar Yilmaz Atali
Pages : 115-121
Doi:10.29228/erd.55
View : 143 | Download : 100
Publication Date : 2023-12-26
Article Type : Research Paper
Abstract :Objectives: This in vitro study was aimed to evaluate the effect of chlorhexidine digluconate (CHX) containing cavity disinfectant on microleakage of Class V self-adhesive resin-based composite restorations. Materials and Methods: Forty non-beveled Class V cavities (4x2x2mm) with occlusal and cervical margins on enamel were prepared on lingual and buccal surfaces of 20 molar teeth. Samples were randomly divided into 4 groups (n=10); and lingual cavities were disinfected with 2% CHX (Bisco). Cavities were restored using 2 different self-adhesive composites: Vertise Flow (Kerr); Activa BioACTIVE (Pulpdent) according to manufacturer’s instructions. Following 20 s polymerization with Valo (Ultradent) LED curing light, finishing and polishing were performed using Finishing Discs (Bisco). Teeth were coated with a nail polish excluding the restoration area and aged in distilled water at 24°C for 6 months. After immersion of the samples in 2% methylene blue solution, they were sectioned longitudinally in buccolingual direction with a diamond saw (Isomet 1000, Buehler). Microleakage on occlusal/gingival margins were scored under x8 and x20 magnification using a stereomicroscope (Leica MZ7.5). For statistical evaluation, Chi-square test was used. The significance level was set at p <0.05. Results: No statistically significant difference was detected between the total microleakage scores at occlusal and gingival margins (p=0.735; 0.944). Likewise, there was no significant difference between the gingival/occlusal margins of the restorations (p=0.216). CHX application did not show any statistically significance between microleakage values in Class V cavities restored with Vertise Flow or Activa BioACTIVE. (p=0.942; 0.577). Conclusions: CHX cavity disinfectant did not prevent microleakage in Class V cavities restored with self-adhesive composites.
Keywords : biyoaktif materyal, kavite dezenfektanı, mikrosızıntı, self adeziv kompoizt, sınıf V kavite

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026