IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Hitit Medical Journal
  • Volume:5 Issue:3
  • A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critic...

A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management

Authors : Seval KOMUT, Nurdan FİDAN
Pages : 202-208
Doi:10.52827/hititmedj.1344000
View : 114 | Download : 28
Publication Date : 2023-10-10
Article Type : Research Paper
Abstract :Objective: The aim of this study is to evaluate the effects of the Coronavirus disease 2019 on sonographic optic nerve sheath diameter measurement and thus avoid possible misleading results in clinical practice. Material and Method: Each volunteer was first evaluated using carotid system color Doppler ultrasonography. Patients with a history of PCR-confirmed Coronavirus disease 2019 infection were classified as group 1 and patients without a history of Coronavirus disease 2019 infection were classified as group 2, and sonographic optic nerve sheath diameter values of both groups were analyzed. Results: Of the 123 patients included in the study, 70 insert ignore into journalissuearticles values(56.9%); were female and 58 insert ignore into journalissuearticles values(43.1%); were male. 83 insert ignore into journalissuearticles values(67.5%); of the patients included in the study were in group 1 and 40 insert ignore into journalissuearticles values(32.5%); were in group 2. The mean sonographic optic nerve sheath diameter values for the groups were 3.53 mm and 3.46 mm, respectively. The sonographic optic nerve sheath diameter differences between the two eyes for the groups were determined to be 0.203±0.139 mm and 0.282±0.2 mm. Conclusion: Due to the variable effects of Severe Acute Respiratory Syndrome Coronavirus-2, the use of sonographic optic nerve sheath diameter measurement in current standards for critical patient management may lead to false-positive or false-negative results.
Keywords : COVID 19, Kritik hasta, Optik sinir, Pandemi, Ultrasonografi

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026