IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Archives of Clinical and Experimental Medicine
  • Volume:5 Issue:2
  • Efficacy of Genetic Sonogram For Predicting Aneuploidy In a High-Risk Pregnancy Population

Efficacy of Genetic Sonogram For Predicting Aneuploidy In a High-Risk Pregnancy Population

Authors : Fama TOKER, Bulat Aytek ŞIK, Yılda Arzu ABA
Pages : 69-74
Doi:10.25000/acem.706112
View : 35 | Download : 14
Publication Date : 2020-08-31
Article Type : Research Paper
Abstract :AİM: This study evaluates the efficacy of genetic sonogram for predicting aneuploidy in high-risk pregnancies. METHODS: This retrospective study included 1363 pregnant women who underwent a second trimester genetic sonogram due to high-risk pregnancy. Sensitivity, specificity, odds ratio, (+) and (-) likelihood ratios were calculated for each of the ultrasonography markers. RESULTS: Among the high-risk pregnancy study population, there was no significant difference regarding advanced maternal age, presence of a relative with Down Syndrome, history of anomaly in the previous pregnancy, hyperechogenic bowels, pyelectasis, nuchal fold thickness > 5 mm, ventriculomegaly, choroid plexus cyst, single umbilical artery, or presence of right echogenic intracardiac focus between the control and aneuploidy groups (p>0.05). Tricuspid regurgitation, hypoplasia/absence of nasal bone, short femur, short humerus and left echogenic intracardiac focus were associated with increased risk of aneuploidy (p<0.05). The risk of aneuploidy was increased by 14.45 fold (95% CI 2.90-71.85) in cases with tricuspid regurgitation, 18.01 (5.46-59.32) fold by hypoplasia/absence of nasal bone, 9.74 (3.70-25.65) fold by presence of short femur, 11.42 (4.30-30.30) fold by presence of short humerus, and 4.20 (1.39-12.64) fold with the presence of left echogenic intracardiac focus. Analysis of combined markers showed that hypoplasia/absence of nasal bone + short humerus + tricuspid regurgitation resulted in the highest risk (OR = 11.20, LHR = 7.53). CONCLUSION: İn some countries, where NIPT are not thoroughly diffused,Genetic sonography is recommended for Down syndrome risk modification in high-risk pregnancies.
Keywords : aneuploidy, pregnancy, genetic sonogram

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026