IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Health Sciences and Management
  • Volume:4 Issue:2
  • Comparison of Two Different Proprioception Measurement Methods in the Shoulder Joint

Comparison of Two Different Proprioception Measurement Methods in the Shoulder Joint

Authors : Talha Kılıç, Tuğba Kuru Çolak, Ali Tekin, Bahar Özgül, Aycan Cakmak
Pages : 36-41
View : 50 | Download : 33
Publication Date : 2024-05-30
Article Type : Research Paper
Abstract :Aim: Proprioception assessment is important in shoulder rehabilitation. Proprioception sense can be evaluated with different methods in the clinical setting. The aim of this study was to compare shoulder proprioception measurements made with universal goniometer and isokinetic system. Methods: A total of 52 healthy individuals with a mean age of 24.6 years were included in the study. Shoulder proprioception was evaluated three times with a universal goniometer and isokinetic device at 30, 45 and 60 degrees shoulder flexion angles with eyes closed in a sitting position and mean values were recorded. Results: When the results obtained with the two measurement methods were compared, it was determined that there was a significant difference between the mean values and there was no correlation relationship between the results of the two measurement methods (p<0.05). However, when the mean deviation from the target angle was compared with both measurement methods, it was determined that there was no significant difference between the measurement methods (p<0.005). Conclusion: The findings of this study demonstrated that when shoulder proprioception was measured using a goniometer or an isokinetic dynamometer at various angles, different values could be obtained. However, since the differences compared to the target angle are similar for the two measurement methods, both assessment methods can be used for proprioception evaluation.
Keywords : değerlendirme, omuz, propriosepsiyon, rehabilitasyon

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026