IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Experimental and Clinical Medicine
  • Volume:34 Issue:3
  • Can we trust the positivity of semi-quantitative glucose measurement in the urine?

Can we trust the positivity of semi-quantitative glucose measurement in the urine?

Authors : Rukiye NAR, Bahattin AVCİ
Pages : 161-164
View : 40 | Download : 13
Publication Date : 2018-07-10
Article Type : Research Paper
Abstract :Objective: As known, when the blood glucose level exceeds the renal threshold value of 180-200 mg/dL begins to be excreted with urine. Spot urine analysis is easy to perform and an important test, with false positive or negative test results incompatible with the clinic. Our aim in this study is to investigate the relationship between glucose levels in different sample types with simultaneous measurements. Material and Method: Simultaneous fasting serum glucose, HbA1c levels and urine glucose of 2375 patients were screened retrospectively from the hospital information system between June 1, 2015 and November 30, 2015. Fasting serum glucose was measured by enzymatic hexokinase method in biochemical autoanalyzer, HbA1c was measured by chromatographic method on HPLC and urine glucose was measured semi-quantitatively by urine autoanalyzer by strip glucose oxidase method. Results: It was found that there was a medium-strong relationship between all three results. There was significant   correlation   between  fasting serum glucose and HbA1c insert ignore into journalissuearticles values(r: 0.787, p <0.001); and the correlation between urinary glucose and fasting serum glucose and HbA1c were insert ignore into journalissuearticles values(r: 635, p <0.001); and insert ignore into journalissuearticles values(r: 533, p <0.001);, respectively. Conclusion: In our study, we indicated that there is a strong correlation between the glucose results of different types of samples that we use in our laboratory. The patient`s concurrently measured HbA1c and fasting serum glucose results may be helpful to the laboratory specialist to avoid both false positives and false negatives.
Keywords : glucose, HbA1c, fasting serum glucose

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026