IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Marmara Medical Journal
  • Volume:34 Issue:1
  • Ultrasound shear-wave elasticity and magnetic resonance diffusion coefficient show strong inverse co...

Ultrasound shear-wave elasticity and magnetic resonance diffusion coefficient show strong inverse correlation in small fibroadenomas

Authors : Nurten ANDAC BALTACIOGLU, Derya TURELI
Pages : 24-28
Doi:10.5472/marumj.866519
View : 46 | Download : 11
Publication Date : 2021-01-29
Article Type : Research Paper
Abstract :Objective: Stiffness of breast lesions helps distinguish malignant from benign solid masses. Stiffness can be quantitatively measured by magnetic resonance and ultrasound imaging using apparent diffusion coefficient insert ignore into journalissuearticles values(ADC); and shear-wave elastography insert ignore into journalissuearticles values(SWE); techniques, respectively. This study aims to analyze correlations between SWE and ADC in biopsy-proven small fibroadenomas. Patients and Methods: Shear-wave elastography and ADC measurements of 50 fibroadenomas were evaluated retrospectively. Mean patient age was 41±13 years insert ignore into journalissuearticles values(range 27-63);. All lesions had maximum diameters of ≤20 millimeters. Correlations between intralesional ADC, lesion-parenchyma ADC ratio, intralesional SWE, SWE heterogeneity index and lesion volume were analyzed. Results: Mean values of lesions were as follows: ADC=1.71±0.22 x10-3mm2/s, ADC ratio=1.04±0.09, maximum SWE=73.4±28.8 kPa, minimum SWE=43.9±21.8 kPa and SWE heterogeneity index =29.4±12.7 kPa. There was a strong inverse correlation between fibroadenoma ADC and SWE values insert ignore into journalissuearticles values(rho = – 0.746, p <0.01);. Significant correlations were also found between fibroadenoma volume and ADC insert ignore into journalissuearticles values(rho = – 0.525, p <0.05); and SWE insert ignore into journalissuearticles values(rho = 0.840, p <0.01);. Conclusion: Apparent diffusion coefficient and SWE values show strong inverse correlation in small fibroadenomas. If proven threshold values for lesion characterization are revealed, ultrasonographic SWE and diffusion-weighted MRI have potential to be used interchangeably.
Keywords : Apparent diffusion coefficient, Fibroadenoma of breast, Magnetic resonance imaging, Ultrasound shear wave elastography

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026