  • Real-Time Communication between S7-1200 PLC and Matlab/Simulink and a Fuzzy Logic Temperature Humidi...

Real-Time Communication between S7-1200 PLC and Matlab/Simulink and a Fuzzy Logic Temperature Humidity Control Application

Authors : Yavuz ÜSER, Cumali KARA
Pages : 7-14
View : 37 | Download : 11
Publication Date : 2019-01-30
Article Type : Research Paper
Abstract :It is not much possible for controllers such as PLC insert ignore into journalissuearticles values(Programmable Logic Controller); and DCS insert ignore into journalissuearticles values(Distributed Control System); used in the industry to solve complex systems. On the contrary, Matlab/Simulink provides advantages with the solutions it offers in the complex systems. It is highly significant that PLCs have a real-time communication with Matlab to solve this kind of complex systems. For industrial automation, interoperability standard OPC insert ignore into journalissuearticles values(OLE for process control); plays the role of a bridge between Matlab/Simulink and PLC and enables data exchange between them.  On the other hand, Fuzzy Logic provides advantage in solving complex systems. There are two inputs in this research. Temperature and relative humidity data is transferred to Matlab/Simulink via OPC by PLCs. Based on the temperature and relative humidity felt depending on the temperature, the percentage of fan speed is calculated by using Fuzzy controller in Matlab/Simulink and transferred to PLC via OPC and the required physical output connected to PLC is activated. This system shows how fast the processes which are complex in PLC can be solved with Matlab/Simulink.  A complex system developed in Matlab/ Simulink can be automatically converted to any microcontroller code.  The PLC used in industry can communicate with this microcontroller as well and obtain the desired output in the best way possible. Nowadays, Artificial Intelligence develops day by day and such a system gains even more importance.
Keywords : S7 1200, Real Time Communication, Complex System, Fuzzy Logic Control, OPC

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.