IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Clinical and Experimental Health Sciences
  • 2013 Doktora Programı Mezunları Special Issue
  • In Vitro Evaluation of Retentive Properties of Different Luting Cements on Zirconia Copings

In Vitro Evaluation of Retentive Properties of Different Luting Cements on Zirconia Copings

Authors : İpek Aksoy, Çoşkun Yıldız
Pages : 0-0
View : 107 | Download : 9
Publication Date : 2016-05-13
Article Type : Research Paper
Abstract :Objectives: The purpose of this in vitro study was to evaluate the retentive properties of zirconia copings luted with different cements against with base metal alloy copings after artificial aging. Methods: Caries-free extracted 120 mandibular premolars were prepared with 6° taper. After preparation, 60 of the specimens were cast in 3Y-TZP, whereas the 60 specimens were cast in an Ni-Cr alloy. Cementation was performed with 3 different luting cements insert ignore into journalissuearticles values(zinc phosphate cement, Panavia F2.0, RelyX U100); in each group. Specimens were thermocycled between +5°C and +55°C for 2500 cycles, with a dwell time of 30 seconds. Dynamic loading of 10 specimens in each subgroup was performed for 100 000 cycles at 50 N at a frequency of 0.5 Hz. Vertical tensile force was applied with a constant speed of 10 mm/min until separation was noted. The data were evaluated by multivariate ANOVA and Post-hoc Bonferroni for comparing quantitative data, Pearson Chi-square Test for qualitative data insert ignore into journalissuearticles values(p<0.05);. Results: The highest mean retentive force for the Ni-Cr alloy copings was observed insert ignore into journalissuearticles values(281.10N); for PAN speciment only received thermocycle; for the zirconia copings was observed insert ignore into journalissuearticles values(171.40N); for ZPC specimen only received thermocycle. Conclusions: Retentive force of Ni-Cr and zirconia was different each other. Also artificial aging affected retentive force and failure modes of Ni-Cr and zirconia copings differently. The mean retentive force of all cements in Ni-Cr group after dynamic loading decreased however all cements in zirconia group had similar mean retentive force values before and after dynamic loading. 
Keywords : Zirconia, Ni Cr alloy, resin cement, retention, artificial aging

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026