Stress distribution of four implant supported overdentures with tilted standard-sized implants and mini implants

Authors : Işıl Turp, Volkan Turp, İlkin Tuncel, Aslıhan Üşümez
Pages : 95-101
Doi:10.26650/eor.20241272144
View : 59 | Download : 40
Publication Date : 2024-05-08
Article Type : Research Paper
Abstract :Purpose: The goal of the current study is to evaluate the stress distribution when tilted implants and mini-implants are used to support a mandibular overdenture. Materials and Methods: Three-dimensional (3D) finite element models of mandibular overdentures were established using four, axial, standard-sized implants (SA model), four standard-sized implants with the mesial ones axial and the distal ones tilted (ST model) and four mini-implants (MA model) with Locator attachments. On each model, a 100 N load was applied to the overdenture in four different directions; bilateral vertical, unilateral vertical and oblique load on the posterior region, and a vertical load on the incisors. The stresses distributed at the peri-implant bone, implants, the prosthetic components, and the overdentures were evaluated. Results: Non-axial posterior loading caused higher stress values in the implant and the prosthetic component than axial posterior loading. Lower stress values of the implant and the prosthetic component were observed in the ST model than SA model. The stress distribution in the overdenture at posterior loads were mostly observed around the implants. Conclusion: Less prosthetic complications may be expected when the treatment option in the ST model is used. Fatigue fractures may occur around the implants in the overdentures, precautions are advised.
Keywords : Açılı implantlar, mini implantlar, sonlu elemanlar analizi, locator, implant üstü tam protez

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.