IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Isı Bilimi ve Tekniği Dergisi
  • Volume:43 Issue:2
  • EFFECT OF INLET VELOCITY PROFILE AND ENTRANCE LENGTH ON ABDOMINAL AORTIC ANEURYSM HEMODYNAMICS SIMUL...

EFFECT OF INLET VELOCITY PROFILE AND ENTRANCE LENGTH ON ABDOMINAL AORTIC ANEURYSM HEMODYNAMICS SIMULATIONS

Authors : Burcu Ramazanli, Cüneyt Sert, M Metin Yavuz
Pages : 159-174
Doi:10.47480/isibted.1391391
View : 153 | Download : 118
Publication Date : 2023-11-17
Article Type : Research Paper
Abstract :In computational Abdominal Aortic Aneurysm (AAA) hemodynamics studies, along with adjusting the problem geometry, mesh, transport, turbulence and rheology models; setting up boundary conditions (BC) is also a very important step which affect the reliability and accuracy of the hemodynamic assessment. The transient effects of physiological flow are well described by the Womersley profile, though its application might be difficult due to the complex nature of functions involved. Conversely, in literature, studies utilizing Plug or Parabolic profiles as inlet boundary conditions generally requires large entrance lengths to obtain the exact characteristics of the Womersley profile. In the current study, the differences arising between those boundary conditions, Womersley, Parabolic and Plug, with different entrance lengths, L_(ent )=D,3D and 11D, are examined by comparing the results with a Base condition, which is a solution obtained with ensured fully-developed flow before entering the aneurysm sac at two physiological flow conditions with mean Reynolds numbers, 〖Re〗_m=340 and 1160. The results reveal that with increasing mean flow rate, applying the complex Womersley equation might not be necessary. For the inlet flow waveform with 〖Re〗_m=1160, the Parabolic profile can be used instead of the Womersley profile by supplying an entrance length L_(ent )= 3D. On the other hand, the Plug profile requires an entrance length at least L_(ent )= 11D to replicate the Base condition for waveform with 〖Re〗_m=340.
Keywords : Abdominal aort anevrizması hemodinamiği, Womersley profili, Duvar kayma gerilmesi parametreleri, Girdap tanımlama yöntemleri

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026