IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Politeknik Dergisi
  • Volume:19 Issue:4
  • An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation

An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation

Authors : Hüseyin Ozan TEKİN, Tugba MANİCİ, Vishwanath P SINGH
Pages : 617-622
View : 39 | Download : 6
Publication Date : 2016-12-01
Article Type : Research Paper
Abstract :Computed tomography insert ignore into journalissuearticles values(CT); related to computer-processed combination or X-ray images obtained from different angles to create patient’s cross-sectional body parts images. CT is mostly associated with high radiation dose to organs during the diagnostic process. To provide the probable effect of bismuth shielding on dose reduction to organs and investigation of applicability of Monte Carlo insert ignore into journalissuearticles values(MC); method. Monte Carlo insert ignore into journalissuearticles values(MC); method has been used for calculation of dose attenuation properties of bismuth. MCNPX insert ignore into journalissuearticles values(version 2.4.0); has been used during the calculations. In this study, validation of modeled MCNPX simulation geometry has been provided by calculating the mass attenuation coefficient values of lung and comparing with previous available studies in literature for lung. Our results agreed well with other results about mass attenuation coefficients of lung. By using the validated MC model, dose attenuation properties of bismuth have been investigated. Dose reduction rates of bismuth on lung have been compared with experimental studies. With bismuth shielding, absorbed dose amount in lung significantly reduced. It can be concluded from MC results that the bismuth shielding reduced lung dose significantly in x-ray CT examination of thorax region
Keywords : Dose Reduction, Bismuth Shielding, Monte Carlo

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026