  • High Energy Efficient System Design for Incubation Process and Cooling of Yoghurt

High Energy Efficient System Design for Incubation Process and Cooling of Yoghurt

Authors : Gülşah KARACA, Ekin Can DOLGUN, Rukiye MAVUŞ, Mustafa AKTAŞ
Pages : 779-784
Doi:10.2339/politeknik.531574
View : 58 | Download : 10
Publication Date : 2020-09-01
Article Type : Research Paper
Abstract :Food processing studies are important for both efficient use of energy and to obtain quality products. Yoghurt is a dairy product which consumes widely. Yoghurt producing facilities consumes high energy and run at low efficiency due to their traditional production methods. In order to produce quality yoghurt, pasteurized milk should be kept at 42-45 oC for 3-5 hours depending on the yeast type, this process called as incubation. After the incubation process, produced yoghurt must be cooled down to 20 oC in two hours depending on the package size of yoghurt. In conventional yoghurt production facilities, required heating and cooling are applied independently and this approach causes high energy consumptions, waste heat and the inefficient use of energy. In this study, a combined system consisting of a heat pump and a heat storage unit which is capable of the simultaneously heating and/or cooling application independently of each other is designed to ensure higher energy performance and efficiency. Thus, the required energy for heat transfer from the evaporator and cooling after the incubation process was ensured from the stored ice and, independently of the weight of the product, 64/68 units of energy insert ignore into journalissuearticles values(depending of refrigerant); were gained for each 100 units of required heating energy.The coefficient of performance insert ignore into journalissuearticles values(COP); of the system using R410a and R134a for heating, cooling and dual operation modes were calculated as 2.83, 1.83, 4.66 and 3.16, 2.16, 5.31, respectively. Energy costs for heat pump and conventional natural gas-fuel-oil boilers were compared. High energy efficiency and low energy consumption have been provided with the presented design, and suggestions for use for production facilities are given.
Keywords : Incubation of yoghurt, energy efficiency, heating, cooling

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.