IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi
  • Volume:25 Issue:2
  • Mediator effect of luteolin on electrooxidation of NADH

Mediator effect of luteolin on electrooxidation of NADH

Authors : Melike BİLGİ KAMAÇ, Gulshat GYLYJOVA
Pages : 453-465
Doi:10.16984/saufenbilder.745610
View : 20 | Download : 11
Publication Date : 2021-04-15
Article Type : Research Paper
Abstract :The effects of luteolin insert ignore into journalissuearticles values(LU); as a new mediator on the electrooxidation of the reduced nicotinamide adenine dinucleotide insert ignore into journalissuearticles values(NADH); were investigated and developed a new disposable NADH sensor. Firstly, screen printed carbon electrodes insert ignore into journalissuearticles values(SPCE); modified with gold nanoparticles insert ignore into journalissuearticles values(AuNP);, and then, LU was deposited on SPCE modified with AuNP insert ignore into journalissuearticles values(SPCE/AuNP); using cyclic voltammetry. Electrochemical behavior of LU on SPCE/AuNP was investigated and, the redox proses of LU on SPCE/AuNP was found to be adsorption controlled. The number of cycles was optimized for the electrochemical deposition of LU and determined to be 15 cycles. LU modified SPCE/AuNP insert ignore into journalissuearticles values(SPCE/AuNP/LU); was found to show the electrocatalytic effect on electrooxidation of NADH and acts as a mediator. Working potential and pH were optimized for electrochemical detection of NADH with the proposed SPCE/AuNP/LU sensor and found to be +0.225 V and 7.25, respectively. The proposed NADH sensor showed a well linear response from 15.90 to 925 μM with a detection limit of 4.57 μM and a sensitivity of 11.19 μAmM−1. The repeatability of the NADH sensor was tested +0.225 V with 50 µM NADH solution. The relative standard deviation insert ignore into journalissuearticles values(RSD); was calculated as 3.68% insert ignore into journalissuearticles values(for n=10);. The operational stability studies have shown that the initial amperometric response of sensor to NADH decreased by 62.1% at the 30th day. The analysis of NADH in artificial human serum samples was successfully performed with SPCE/AuNP/LU sensor.
Keywords : NADH, luteolin, gold nanoparticles, redox mediator, human blood serum

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025