IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi
  • Volume:9 Issue:1
  • Shear bond strength of veneer composite to cobalt-chromium alloys fabricated differently

Shear bond strength of veneer composite to cobalt-chromium alloys fabricated differently

Authors : Ayça TULGA
Pages : 34-39
Doi:10.22312/sdusbed.290849
View : 16 | Download : 13
Publication Date : 2018-04-17
Article Type : Research Paper
Abstract :ABSTRACT Objective: The purpose of this study was to assess and contrast the shear bond strength of a veneer composite resin bonded to cobalt-chromium insert ignore into journalissuearticles values(CoCr); dental alloys produced by different techniques. Material-Method: Ninety cylindrical specimens insert ignore into journalissuearticles values(10mm in diameter, 8mm in height); made of CoCr dental alloys were prepared by casting insert ignore into journalissuearticles values(C);, milling insert ignore into journalissuearticles values(M);, LaserCUSING with and without annealing insert ignore into journalissuearticles values(CL+, CL);, and direct metal laser sintering insert ignore into journalissuearticles values(DMLS); with and without annealing insert ignore into journalissuearticles values(EL+, EL);. Veneer composite cylinders insert ignore into journalissuearticles values(5mm in diameter, 3mm in height); were built on metal specimens using a silicone jig. After storage in water for 24 hours, the specimens were assessed for bond strength with a shear force test at a crosshead speed of 0.5 mm/min. The shear bond strengths insert ignore into journalissuearticles values(SBSs); were statistically analyzed using the Kolmogorow-Smirnow test and Tukey-HSD multiple comparison test insert ignore into journalissuearticles values(α=.05);. Results: When the SBS values of the groups were compared, significant differences were found among the groups insert ignore into journalissuearticles values(P<.05);. While statistically significant differences were found between the CL+ group insert ignore into journalissuearticles values(9.36 ∓ 2.62); and the M group insert ignore into journalissuearticles values(13.34 ∓ 2.53); insert ignore into journalissuearticles values(P<.05);, there were no significant differences among the others insert ignore into journalissuearticles values(P>.05);. The debonded surfaces of the specimens exhibited mostly mixed failure types. Conclusions: The CoCr alloy fabrication technique has an effect on the SBSs between the veneer composite resin and the metal used. LaserCUSING casting, a new technology, seems to have the lowest metal-resin bond strength among all the techniques tested.
Keywords : Cobalt chromium alloys, direct metal laser sintering, milling, shear bond strength

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025