IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Anatolian Current Medical Journal
  • Volume:6 Issue:1
  • Temporal alterations in P-wave electrocardiographic metrics post patent foramen ovale closure: a ret...

Temporal alterations in P-wave electrocardiographic metrics post patent foramen ovale closure: a retrospective study

Authors : Aslan Erdoğan, Ömer Genc
Pages : 87-92
Doi:10.38053/acmj.1405564
View : 77 | Download : 62
Publication Date : 2024-01-15
Article Type : Research Paper
Abstract :Aims: This study aimed to analyze the electrocardiograms (ECG) of 69 patients before and after patent foramen ovale (PFO) closure, specifically investigating novel ECG parameters, over a 6-month post-procedure period. Methods: ECGs from 69 patients undergoing PFO closure were examined at three time points: before the procedure, and at 1st and 6th months post-procedure. A comprehensive set of ECG parameters, including P-wave (PW) maximum (PWmax), PW minimum (PWmin), PR interval, PW dispersion (PWdis), PW peak time in lead D2 (PWPTD2), PW peak time in lead V1(PWPTV1), P-axis, PW terminal force in the V1 (PWTF) and heart rate, were analyzed using a generalized linear mixed model (GLMM). Results: The GLMM analysis revealed significant changes in novel ECG parameters at 1-month post-procedure compared to baseline values. Parameters including PWmax (OR=8.898, 95% CI 7.521-10.275, p<0.001, PWmin (OR=6.579, 95% CI 5.611-7.548, p<0.001), PR (OR=4.159,95% CI 3.031-5.288, p<0.001), PWdis (OR=2.594, 95% CI 1.607-3.581, p<0.001), PWPTD2 (OR=4.261, 95% CI 2.928-5.593, p<0.001), PWPTV1 (OR=5.261, 95% CI 4.529-5.992, p<0.001), and PWTF (OR= 5.781, 95% CI 2.083-16.044, p<0.001) exhibited notable alterations, indicating a transient impact on cardiac conduction. However, these changes returned to baseline values by the 6-month follow-up. No statistically significant differences were observed in P-axis and heart rate across all time points. Conclusion: The analysis of ECG in patients undergoing PFO closure highlighted dynamic changes in novel ECG parameters in the early post-procedural period, with subsequent normalization by 6 months. Further research is warranted to elucidate the clinical implications of these dynamic electrocardiographic shifts and their potential association with long-term cardiovascular outcomes.
Keywords : Atrial fibrillation, patent foramen ovale, p wave, stroke

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025