IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Uluslararası Mühendislik Araştırma ve Geliştirme Dergisi
  • Volume:7 Issue:2
  • A Comperative Study on the Behavior of Cooling Towers Under Wind Loads Using Harmonic Solid Ring Fin...

A Comperative Study on the Behavior of Cooling Towers Under Wind Loads Using Harmonic Solid Ring Finite Elements

Authors : Ali İ KARAKAS, Ayse DALOGLU
Pages : 20-29
Doi:10.29137/umagd.346129
View : 20 | Download : 15
Publication Date : 2015-06-15
Article Type : Research Paper
Abstract :The present work focuses on a comparative study for the responses of a cooling tower subjected to wind loadings described in accordance with Turkish Standard insert ignore into journalissuearticles values(TS 498); and Eurocode using harmonic solid ring finite elements. Nonaxisymmetric wind loadings around the circumference make the cooling tower problem three dimensional. However, using harmonic elements reduces the problem to a two dimensional problem by expressing the loading in the form of a Fourier series. Therefore, a finite element program is coded in M atlab incorporating harmonic finite element techniques. The wind analyses of the cooling tower are conducted using 9-noded harmonic solid ring finite element modeling. The harmonic finite element formulations in general terms are presented in the study. The vertical and circumferential distributions of the wind loading effective on the cooling tower according to both standards are compared. The circumferential distributions are expressed using Fourier cosine series and the coefficients indicate that while the wind loading mainly will cause undulating deformations according to Eurocode and beam like deformations according to Turkish Standard insert ignore into journalissuearticles values(TS 498);. M oreover, it is realized that the circumferential distribution of wind pressure influenced the magnitude of displacements and stresses significantly as well as the region under tension along the circumference of the cooling tower.
Keywords : Wind load, cooling tower, harmonic solid ring finite elements

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025