IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Uluslararası Mühendislik Araştırma ve Geliştirme Dergisi
  • Volume:9 Issue:2
  • The Temperature-Pressure-Frequency Relationship Between Electrical Power Generating in Stirling Engi...

The Temperature-Pressure-Frequency Relationship Between Electrical Power Generating in Stirling Engines

Authors : Mehmet Sait CENGİZ, Mehmet Salih MEMİŞ, Metin KAYNAKLI
Pages : 59-64
Doi:10.29137/umagd.351745
View : 19 | Download : 8
Publication Date : 2017-06-15
Article Type : Research Paper
Abstract :Normal 0 21 false false false TR X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:`Normal Tablo`; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:``; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:8.0pt; mso-para-margin-left:0cm; line-height:107%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:`Calibri`,sans-serif; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:`Times New Roman`; mso-bidi-theme-font:minor-bidi; mso-fareast-language:EN-US;} In this research, the variation of electrical power according to temperature, pressure, frequency, and cooler temperature, in Stirling engines was analyzed. The performance characteristics of the low power beta type Stirling engine were determined by gas exchange in this research, and the results were compared and presented by graphics. The performance tests of the Stirling engine heated by using the thermal specification of the sun were realized as 673 K, 773 K, and 873 K for the heater temperatures. The charge pressure was increased from 100 kPa up to 400 kPa with the ranges of 100 kPa. The maximum power was calculated by taking the frequency of crankshaft 10, 30, 50, and 60. Also, the electrical power increase was provided by raising the temperature difference between the hot edge of the displacer and the cooler temperature.
Keywords : Stirling engines, renewable energy, solar systems, heat engines

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025