IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Uluslararası Mühendislik Araştırma ve Geliştirme Dergisi
  • Volume:15 Issue:2
  • Investigation of Temperature and Stress Distributions in a Dental Implant Prosthesis

Investigation of Temperature and Stress Distributions in a Dental Implant Prosthesis

Authors : İkram TAŞDEMİR, Cemalettin AYGÜN
Pages : 584-597
Doi:10.29137/umagd.1276612
View : 56 | Download : 56
Publication Date : 2023-07-14
Article Type : Research Paper
Abstract :Todays, the increasing success rates, and intensity of use of implant applications have attracted attention in the field of dentistry to dental implants. In this study, the temperature and stress distribution in a dental implant was modeled in three dimensions using the commercial software Ansys, which uses the finite element method. The changes in the implant prosthesis were investigated by applying a 100N load to the model and a temperature of 45o C and 10o C, respectively. The temperature input condition was accepted as the temperature of freshly taken food/beverage from the stove for the highest temperature and the temperature of freshly taken out of the refrigerator for the lowest temperature. As a result of the analyzes insert ignore into journalissuearticles values(Fluid Flow);, it was observed that the implant prosthesis didn’t conduct heat to the tooth root at 45o C and 10o C. As a result of the von Mises stress distribution and total deformation analysis under a load of 100 N, it was determined that the tensile and compressive strength was good insert ignore into journalissuearticles values(48.17 MPa);, and most of the applied load was supported by the artificial tooth crown. The chewing force applied due to its structure from the tooth geometry causes non-homogeneous stress distribution in all axes. Thus, it reveals that mechanical compatibility is of great importance as well as biocompatibility. Titanium alloys insert ignore into journalissuearticles values(Ti-6Al-4V);, which are frequently used in tooth crowns and tooth roots, cause differentiation in bone structure together with the formation of a protective oxide layer. Considering the loss of bone volume and resorption diseases, especially during the osteoporosis/menopause, it is possible that a problem may occur at the implant-bone interface.
Keywords : Diş Protezi, Sonlu elemanlar Analizi, Isıl ve Gerilme Analizi, Ti 6Al V, Tek Diş

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025