IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Bilge International Journal of Science and Technology Research
  • Volume:7 Issue:1
  • Simulation of Load Behavior Based on Perturb-Observation Method in Non-Isolated Boost Converter for ...

Simulation of Load Behavior Based on Perturb-Observation Method in Non-Isolated Boost Converter for Maximum Power Point Tracking of Thermoelectric Generators

Authors : Hayati MAMUR, Çiğdem AKYILDIZ, Mehmet Ali ÜSTÜNER
Pages : 70-77
Doi:10.30516/bilgesci.1201697
View : 25 | Download : 14
Publication Date : 2023-03-31
Article Type : Research Paper
Abstract :The efficiency of thermoelectric generators insert ignore into journalissuearticles values(TEGs); is quite low. To operate the TEGs at the maximum power point insert ignore into journalissuearticles values(MPP);, the internal resistance of the connected load and the TEG must be equal. This is not always possible. For this, converters containing the maximum power point tracking insert ignore into journalissuearticles values(MPPT); algorithm tracking MPP are placed between the TEG and the load. These converters cannot perform MPPT on every connected load value. The aim of this study is to investigate at which load values MPPT can be performed in non-isolated boost converters by using perturb & observation insert ignore into journalissuearticles values(P&O); method. For this purpose, a 50 W converter was designed with a 45.76 W TEG in MATLAB/Simulink environment. Load resistance value has been increased starting from the minimum value up to 5.84 ohm being the internal resistance value of the TEG. For this case, the amount of error in MPPT was large up to the internal resistance value of the TEG. In other words, the P&O algorithm could not perform MPPT. When the load resistance value started from 5.84 ohms and increased to larger values, MPPT could be performed by means of the non-isolated boost converter with the P&O algorithm.
Keywords : Thermoelectric generator, MPPT, Boost converter, Load limit

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025