IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Eurasian Journal of Critical Care
  • Volume:1 Issue:2
  • Central Venous Catheter Malposition: Two Case Reports

Central Venous Catheter Malposition: Two Case Reports

Authors : Semih AYDEMİR, Yavuz KATIRCI
Pages : 91-94
View : 25 | Download : 12
Publication Date : 2019-09-03
Article Type : Other Papers
Abstract :Introduction: Unintended vessel advancement during central venous catheter insert ignore into journalissuearticles values(CVC); insertion is a rare but serious complication.  To reduce the complications whileCVC placement, the practitioner should be experienced. After the placement it is required to verify correctness. Case Presentation : ·          Case 1: A 65-year-old male patient who returned as hypotensive after cardiopulmonary resuscitation was planned with CVC insertion formonitoring central venous pressure, fluid replacement and inotropic support. As the patient’s hemostatic parameterswere normal, catheter was placed into the right subclavian vein. Posterior-anterior chest radiographinsert ignore into journalissuearticles values(CR); was used to confirm catheterization site. It was found that catheter tip was not in normal position, right internal jugular veininsert ignore into journalissuearticles values(IJV); was directed and twisted in two places. ·          Case 2: A 64-year-old patient with respiratory distress was conscious of consciousness. The patient’s hemostasis parameters were normal and was placed central catheter into right internal jugular vein insert ignore into journalissuearticles values(IJV);. It was seen by theCR that catheter tip was not in the correct position and it was directed to the right subclavian vein. Discussion: One of the most common complications during CVC placement is malposition of the catheter. Placing a CVC is an invasive procedure and it should be remembered that various complications may develop during or after the placement.Moreover, practitioners should remember that malposition may not be noticed if no imaging and checking methods are used during CVC administration. Conclusion: It is important that the accuracy of the position of the CVC should be confirmed with post-procedure CR. Thus, any complications that require emergent intervention like malposition or pneumothorax can be detected early. 
Keywords : Central venous catheter, malposition

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025