IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Hacettepe Journal of Biology and Chemistry
  • Volume:48 Issue:2
  • A Polymeric Adsorbent for Removal and Recovery of Nickel from Aqueous Media

A Polymeric Adsorbent for Removal and Recovery of Nickel from Aqueous Media

Authors : Berna SARAÇOĞLU KAYA
Pages : 159-169
Doi:10.15671/hjbc.634459
View : 25 | Download : 8
Publication Date : 2020-04-19
Article Type : Research Paper
Abstract :The Interpenetrating Polymer Network insert ignore into journalissuearticles values(IPN); structure was obtained by gamma radiation of solution of polyethylene glycol insert ignore into journalissuearticles values(PEG);insert ignore into journalissuearticles values(35000MW); in an acrylonitrile insert ignore into journalissuearticles values(AN); to 14 and 60kGy doses were amidoximated with hydroxylamine solution at optimum amidoximation conditions. Effects of pH insert ignore into journalissuearticles values(2-10); and mNi/mIPN ratio insert ignore into journalissuearticles values(0.002-0.5); in Ni 2+ adsorption were examined by batch process and optimum values were determined as 8 and 0.4 for both doses, respectively. Also, the effect of flow rate to Ni 2+ adsorption was examined by the reflux flow process with a fixed-bed reactor at room temperature. Optimum flow rate is determined as 6mL/s at optimum pH. Ni 2+ adsorption studies were carried out in batch insert ignore into journalissuearticles values(pH=6 and 8); and flow insert ignore into journalissuearticles values(pH=8); systems. Maximum adsorption values reached for irradiated to 14 and 60kGy doses and amidoximated IPNs were given as 105 and 99 mgNi/gIPN in batch system insert ignore into journalissuearticles values(pH=6);, 378 and 361 mgNi/gIPN in batch system insert ignore into journalissuearticles values(pH=8); and 891 and 673mgNi/gIPN in flow system insert ignore into journalissuearticles values(pH=8);, respectively. Maximum elution efficiency was obtained for HCl as being 99.5% and 66.1% for IPNs irradiated to 14 and 60kGy doses and amidoximated, respectively. FTIR results showed that HCl caused structural deformation. Minimum elution efficiency was obtained for insert ignore into journalissuearticles values(NH 4 ); 2 CO 3 as being 60.1% and 58.2% for IPNs irradiated to 14 and 60kGy, respectively, by the minimum deformation.
Keywords : IPN, nickel, adsorption, elution

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025