IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • International Journal of Computational and Experimental Science Engineering
  • Volume:9 Issue:3
  • Method Validation and Measurement Uncertainty for the Determination of Ethanol in Whole Blood

Method Validation and Measurement Uncertainty for the Determination of Ethanol in Whole Blood

Authors : Yeter EROL ÖZTÜRK
Pages : 253-257
View : 43 | Download : 31
Publication Date : 2023-09-30
Article Type : Research Paper
Abstract :Alcohol intake is known to significantly affect driving ability and there is a relationship between Blood Alcohol Concentration insert ignore into journalissuearticles values(BAC); and the risk of road traffic accidents car accidents. Alcohol intake is known to significantly affect driving ability. Therefore, many countries define and monitor the legal BAC value for drivers. Customers or legal authorities require determining and reporting the measurement uncertainty in blood alcohol analysis from laboratories in recent years. In order to ensure the reliability and safety of the result, the method was validated and the measurement uncertainty was calculated. A rapid, selective and robust gas chromatography coupled with flame ionisation detection method was developed and validated for the quantitative determination of ethanol in whole blood. The method was validated for selectivity, matrix effect, recovery, and linearity, limit of detection insert ignore into journalissuearticles values(LOD);, limit of quantification insert ignore into journalissuearticles values(LOQ);, recovery, repeatability, reproducibility and robustness. The validation procedure was designed to be suitable for ISO 17025 accreditation. Uncertainty measurements were also determined for the validated method. LOD and LOQ were found 3.99 mg/dL and 4.30 mg/dL, respectively. The method showed good linearity in the range of 3.9 to 393.7 mg/dL ethanol with a correlation coefficient insert ignore into journalissuearticles values(r2 = 0.9999);. The method provides fast, precise, simple, robust and unbiased results.
Keywords : Whole Blood, Ethanol, HS GC FID, Validation, Uncertainty

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025