IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • International Journal of Health Services Research and Policy
  • Volume:2 Issue:1
  • EFFECTIVENESS OF UMBILICAL ARTERY DOPPLER EXAMINATION, CARDIOTOCOGRAPHY AND AMNIOTIC FLUID INDEX APP...

EFFECTIVENESS OF UMBILICAL ARTERY DOPPLER EXAMINATION, CARDIOTOCOGRAPHY AND AMNIOTIC FLUID INDEX APPLIED IN EARLY INTRAPARTUM PERIOD IN DIAGNOSIS OF FETAL DISTRESS

Authors : Yılda Arzu ABA, Sezgin DURSUN, Bulat Aytek ŞIK, Baki ERDEM
Pages : 29-36
Doi:10.23884/ijhsrp.2017.2.1.05
View : 20 | Download : 11
Publication Date : 2017-06-03
Article Type : Research Paper
Abstract :The present study aims to find an alternative solution to continuous monitoring with Cardiotocography insert ignore into journalissuearticles values(CTG); during intrapartum management process of pregnant women with no previous antenatal follow-up, and to diagnose low-risk pregnancies and avoid the financial burden and discomfort to the pregnant woman resulting from continuous monitoring. Randomly selected 114 term pregnant women with expected vaginal delivery, singleton pregnancies and no major fetal abnormalities were included in the study. Routine obstetric ultrasonography insert ignore into journalissuearticles values(USG); and uterine artery insert ignore into journalissuearticles values(UA); doppler measurements were administered. The pregnant women included in the study had an average gestation period of 38.3 ± 1.3, average age of 26.1 ± 5.3, average parity of 2.1 ± 1.5 and average infant birth weight of 3280 ± 442 g. 13 pregnant women were considered to have fetal distress following continuous monitoring with cardiotocography. Furthermore, decreased amniotic fluid index was detected in 9 of them. 10 cases were assessed to be pathological as a result of Uterine Artery Doppler examination. In two cases deemed pathological, fetal distress developed and found to be statistically insignificant. No statistically significant difference was found between decreased amniotic fluid index cases and non-decreased amniotic fluid index cases in terms of C-section application due to fetal distress. In our study, Cardiotocography + Amniotic Fluid Index measurement was determined to be the most valuable combination as the delivery room admission test. 
Keywords : Fetal distress, intrapartum period, amniotic fluid index, Cardiotocography, Umblical Artery Doppler Examination

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025