4E Analysis of Power and Water Cogeneration Plant based on Integrated MED-TVC and RO Desalination Units

Authors : Hossein VAZİNİ MODABBER, Mohammad Hasan KHOSHGOFTAR MANESH
Pages : 107-126
Doi:10.5541/ijot.616899
View : 15 | Download : 8
Publication Date : 2020-05-28
Article Type : Research Paper
Abstract :In this study, integration of RO desalination unit with power and water cogeneration plant located in Qeshm Island in Iran has been investigated. The desalination unit exists in this plant is MED-TVC type. In this regard, energy, exergy, exergoeconomic, and exergoenvironmental insert ignore into journalissuearticles values(4E); analyses have been performed by developing a computer code using Matlab. Validation of thermodynamic data has been performed through comparing the results of modeling by Matlab with the simulation done in Thermoflex software and the real data gathered from the Qeshm cogeneration plant. The results show the acceptable accuracy of thermodynamic modeling. The exergoenvironmental analysis has been conducted based on Life Cycle Assessment insert ignore into journalissuearticles values(LCA);. In this regard, the weight function of TVC is proposed in this paper based on technical data in different nominal sizes in order to estimate the environmental impacts of this component. The cogeneration plant produces 25.7 MW power, consuming 6 kg/s steam can lead to production of 51.7 kg/s desalinated water. The gained output ratio insert ignore into journalissuearticles values(GOR); is about 8.7 for the MEDTVC unit. The performance ratio insert ignore into journalissuearticles values(PR); of RO desalination unit which is added to the downstream of MED-TVC has been calculated about 0.5. Integrating RO desalination unit with MED-TVC enhances the production of fresh water by 255.132 ton per hour. Exergetic efficiency, total cost rate of the system and total environmental impact rate of the system has been calculated 46.86 %, 64.01 $/min and 29.49 pts/min, respectively. Since the largest share of exergy destruction rate of the system belongs to the gas cycle and also Qeshm Island has a warm and muggy climate, adding a chiller type air cooling system to inlet of air compressor can decrease the power demand of air compressor and fuel consumption of combustion chamber which makes the system more efficient and reduce the cost and environmental impact rate of the system.
Keywords : Cogeneration, MEDTVC desalination, RO desalination, exergy analysis, exergoeconomic analysis, Life Cycle Assessment

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.