IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Basic and Clinical Health Sciences
  • Volume:3 Issue:2
  • Optimization of Different Surface Modifications for Binding of Tumor Cells in a Microfluidic Systems

Optimization of Different Surface Modifications for Binding of Tumor Cells in a Microfluidic Systems

Authors : Hanife Ecenur MECO, Aslıhan KARADAG, Sevde OMEROGLU, Gizem AYDEMİR, Gizem Calibasi KOCAL, Muhammed Enes ORUC, Huseyin UVET, Yasemin BASBİNAR
Pages : 73-77
Doi:10.30621/jbachs.2019.601
View : 19 | Download : 6
Publication Date : 2019-06-01
Article Type : Research Paper
Abstract :Objectives:Microfluidic technology is a fast-growing area and provide high-efficient MEMS Micro-Electro-Mechanical-Systems sensor integration platform that helps to advance healthcare systems. Due to proper the chemical and mechanical properties of polymers, PDMS Polydimethylsiloxane 6 and PMMA Poly-methyl-methacrylate , they became on the best candidate for health care studies in microfluidic studies 7 . Besides, they perform great optical properties for observation of living cell experiments. To increase their performance, surface interactions works with cells, modification techniques are widely used in microfluidic chips. In this paper, our primary purpose is to modify such polymers and glass with matrigel, PDA and APTES so as to increase cell-surface interaction.Patients and Methods:Cells were seeded into the micro-channels that is modified with 1%, 3% and 5% matrigel. The cell culture were observed 48-hours and images were taken. In the next stage, static culture experiments were performed on glass surfaces modified with PDA polydopamine and APTES 3-Aminopropyl triethoxysilane . 3-hour images were received.Results:The area filled by the cells was calculated using the ImageJ software ver.1.149. In the Matrigel modified chips, at the end of the 48th hour, the surface area of the cells reached to 22.58%-29.14- 26.97% for the matrigel sample rates 1%, 3% and 5%, respectively. In PDA, APTES modified surfaces dissolved in ethanol and APTES modified surface dissolved in water , the cells overlaid on surface after 3rd hour 5,32% 8,08%; and 3,33%, respectively.Conclusion:The tendency of the cells to attach and colonize on increasing matrigel concentrations and on PDA, APTES modified surfaces was higher than the unmodified surface
Keywords : Microfluidic Chips, Surface Modification, Cell Culture

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025