IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Energy Systems
  • Volume:6 Issue:1
  • Performance of a combined power and cooling system under solar, solar storage and storage mode of op...

Performance of a combined power and cooling system under solar, solar storage and storage mode of operations

Authors : Tapan GOGOİ, Utpal DUTTA
Pages : 18-32
Doi:10.30521/jes.952032
View : 17 | Download : 7
Publication Date : 2022-03-31
Article Type : Research Paper
Abstract :In this study, the performances of a combined power and cooling system are compared at solar, solar storage insert ignore into journalissuearticles values(SS);, and storage mode of operations using therminol–LT insert ignore into journalissuearticles values(TLT); and solar salt as storage media. In the solar mode, the entire water heated in a collector field is used to drive subsequently an organic Rankine cycle and an absorption cooling system. In the SS mode during high radiation insert ignore into journalissuearticles values(950 W/m2);, thermal energy storage insert ignore into journalissuearticles values(TES); is used to store a fraction of hot water for later use during the storage mode at nighttime. The system produced 1.1 MW of power and 2.455 MW of cooling during the solar mode at low radiation insert ignore into journalissuearticles values(640 W/m2);. At the SS mode, with TLT as a storage fluid, the power increased to double, however the cooling reduced by 12.22%. During the storage mode, the TLT based system produced 0.553 MW of cooling. During the SS mode with solar salt, the power and cooling increased, however, the nighttime cooling reduced significantly with solar salt. The total energy and the overall system efficiency was more with solar salt compared to those of TLT. The energy output and the system efficiency were the maximum at 950 W/m2 without TES.
Keywords : Combined power and cooling, Organic rankine cycle, Performance, Solar absorption cooling system

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025