IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Health Sciences and Medicine
  • Volume:6 Issue:5
  • The transition from gel separatory serum tubes to lithium heparin gel tubes in the clinical laborato...

The transition from gel separatory serum tubes to lithium heparin gel tubes in the clinical laboratory

Authors : Oğuzhan ZENGİ
Pages : 998-1009
View : 42 | Download : 51
Publication Date : 2023-09-28
Article Type : Research Paper
Abstract :Aims: To assess the viability of replacing serum samples with plasma samples in various clinical chemistry and immunoassay tests and to examine the implications of turnaround time insert ignore into journalissuearticles values(TAT); and sample quality during the transition process. Methods: We compared the results of 27 paired clinical chemistry and 13 immunoassay tests from samples obtained using gel separator serum and gel separator lithium heparinized plasma insert ignore into journalissuearticles values(LIH); tubes. We used regression analysis, bias values, and Bland-Altman plots to compare the performance of serum and LIH tubes in various clinical chemistry and immunoassay tests. We collected and evaluated sample aspiration errors, hemolysis index values, and TAT data from the laboratory information system before and after switching to plasma in our study. Results: Most tests showed no significant difference between the serum and LIH. However, for some analytes, total error insert ignore into journalissuearticles values(TE); values exceeded the total allowable error insert ignore into journalissuearticles values(TEa); limits derived from the biological variation database. Notably, insulin TE value did not exceed TEa, but it consumed near all its error budget. Consequently, we determined the alternative allowable error limits for some tests and found that plasma tubes could be used instead of serum tubes for most tests, except for lactate dehydrogenase insert ignore into journalissuearticles values(LDH);. Plasma tubes improved the sample quality, reduced the incidence of aspiration errors, and decreased TAT in the emergency laboratory. We observed significant reductions in TAT after switching to plasma tubes. Conclusion: Our study showed that LIH tubes can replace serum tubes in most clinical chemistry and immunoassay tests. Using LIH tubes in clinical laboratories can improve healthcare quality and reduce the workload of the laboratory staff.
Keywords : Plasma, serum, total error, turnaround time, sample quality

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025