IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Naval Sciences and Engineering
  • Volume:18 Issue:2
  • THE EFFECT OF FOV ANGLE ON A RSSI-BASED VISIBLE LIGHT POSITIONING SYSTEM

THE EFFECT OF FOV ANGLE ON A RSSI-BASED VISIBLE LIGHT POSITIONING SYSTEM

Authors : Özlem AKGÜN
Pages : 205-230
View : 12 | Download : 8
Publication Date : 2022-11-30
Article Type : Research Paper
Abstract :The effect of field of view insert ignore into journalissuearticles values(FOV); angle on the positioning performance in a visible light positioning insert ignore into journalissuearticles values(VLP); system utilizing light-emitting diodes insert ignore into journalissuearticles values(LEDs); is examined. Due to its simplicity and low cost, the received signal strength indication insert ignore into journalissuearticles values(RSSI); technique with trilateration is used for distance measurement. Since being robust to noise sources, the optical code division multiple access insert ignore into journalissuearticles values(CDMA); is preferred for broadcasting the unique identification and location information of each LED at the same time. LEDs are deployed on the ceiling of a highly reflective room with the aim of providing homogenous and suitable lighting. The varying angle of FOV - 30 degrees up to 88 degrees with 2-degree increments - is considered in the photodetector insert ignore into journalissuearticles values(PD); to obtain the effect of FOV on six different VLP scenarios with respect to the number of LEDs. All scenarios have the non-line of sight insert ignore into journalissuearticles values(NLOS); channel models up to three reflections. Simulation results show that increasing the number of transmitters insert ignore into journalissuearticles values(Txs); decreases the distance error sensitivity to the changes in the FOV angle. Consequently, indoor scenarios with increased Txs allow the use of low FOV angles. Acceptable distance errors are obtained even in harsh conditions, i.e., near the corner of the room.
Keywords : Visible Light Positioning, Field of View Angle, Received Signal Strength Indication, Non Line of Sight Channel Model

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025