  • Journal of Medicine and Palliative Care
  • Volume:5 Issue:2
  • Persistent iatrogenic atrial septal defect after cryoballoon ablation for atrial fibrillation

Persistent iatrogenic atrial septal defect after cryoballoon ablation for atrial fibrillation

Authors : Görkem Yıldız, Başar Candemır, Demet Menekse Gerede
Pages : 118-123
Doi:10.47582/jompac.1446976
View : 42 | Download : 66
Publication Date : 2024-04-30
Article Type : Research Paper
Abstract :Aims: Pulmonary vein isolation (PVI) by cryoballoon ablation (CB) technology is effective and safe treatment option for atrial fibrillation (AF). CB is performed by large diameter, 15Fr (4.95mm) transseptal sheath that may lead to creation of iatrogenic atrial septal defect (iASD). The objective of this study was to assess the incidence of iASD in patients who had undergone CB. Methods: Patients with AF having undergone Arctic Front® CB ablation and a subsequent transesophageal echocardiography (TEE) examination during post-ablation follow up period were consecutively enrolled. During all CB procedures, 15Fr transseptal sheath (Flex Cath, Medtronic, Minneapolis, MN) was utilized via single transseptal puncture (TsP). Results: Twenty-eight patients (15 females, mean age 55.8+15.5) with paroxysmal (n=24) or persistent (n=4) AF formed study group. iASD was present 11 (39.3%) of them after mean follow-up time of 17.3+6.2 months. The procedural time is significantly longer in patient with iASD (119.0+8.8 minutes, p=0.01). No patients died or suffered from any clinically significant cerebral ischemic event. There was no sign of increase in systolic pulmonary arterial pressure (sPAP). Conclusion: iASD after CB was found to be present in 39.3% of patient during a mean follow-up time of 17.3+6.2 months. The prolonged CB procedural time was the only factor that predicted iASD in our study. No adverse clinic events that might be related to iASD was observed during follow-up period.
Keywords : İyatrojenik atriyal septal defekt, kriyobalon ablasyon, pulmoner ven izolasyon, atriyal fibrilasyon

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.