IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Journal of Experimental and Clinical Medicine
  • Volume:29 Issue:1
  • Hipokrat 2000 total knee arthroplasty in gonarthrosis: midterm follow-up results

Hipokrat 2000 total knee arthroplasty in gonarthrosis: midterm follow-up results

Authors : Yılmaz ŞAHİN, Birol GULMAN, NTurgut KARAİSMAİLOGLU, Nevzat DABAK, Yılmaz TOMAK, Ahmet PİŞKİN, Murat ERDOGAN
Pages : 1-5
Doi:10.5835/jecm.omu.29.01.001
View : 104 | Download : 9
Publication Date : 2012-04-17
Article Type : Research Paper
Abstract :The aim of this study is to assess the mid-term results of Hipokrat 2000 total knee arthroplasty applications in gonarthrosis cases. Between February 2000 and January 2004 in Department of Orthopedics, Medical Faculty, Ondokuz Mayıs University, Hipokrat 2000 total knee arthroplasty was applied to 68 knees insert ignore into journalissuearticles values(31 right, 37 left); of total 54 patients insert ignore into journalissuearticles values(49 female, 5 male); with the diagnosis of gonarthrosis. The average age of the patients at the time of surgery was 63.5 insert ignore into journalissuearticles values(distribution 49-80);. Etiological reason was determined to be primary osteoarthritis in 49 patients and rheumatoid arthritis in 5 patients. Patellar component was used in 63 of the cases. The cases were assessed before and after the surgery in accordance with clinical and radiological evaluation and scoring system of the Knee Society. The average follow-up period was 52.6 months insert ignore into journalissuearticles values(distribution 28-76 months);. In accordance with clinical evaluation system of the Knee Society, in 61 of the 68 knees insert ignore into journalissuearticles values(89.7%); the result was good or excellent, in 5 patients insert ignore into journalissuearticles values(7.3%); the result was fair, in 2 patients insert ignore into journalissuearticles values(2.9%); the result was poor. An increase of average 56.7 degrees in knee scores and average 52.1 degrees in function scores was detected. Average 37.5 degrees of increase was detected in the range of movement in comparison to pre-operation. The average alignment angle in the knees was found to be 4.68 degrees valgus. As complications; in one patient patellar subluxation, in one patient superfi cial infection, in one patient deep infection and in one patient deep vein thrombosis were seen. When studies carried out with other semi constrained, posterior cruciate ligament retaining surface replacement prosthesis brands in literature were reviewed; the fact that the clinical and radiological results of Hipokrat 2000 total knee arthroplasty are good shows that it is an appropriate prosthesis for advanced gonarthrosis cases.
Keywords : Gonarthrosis, Knee, Knee prothesis, Total knee arthroplasty

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026