  • Assesment of the heart volume using computerized tomography and magnetic resonance imaging

Assesment of the heart volume using computerized tomography and magnetic resonance imaging

Authors : Fikri OZDEMIR, Micheal MAZONAKIS, Bunyamin SAHIN, Amani ELFAKI, Ozcan YILMAZ, Mustafa Bekir SELCUK
Pages : 0-0
Doi:10.5835/jecm.v2i31.5000068757
View : 36 | Download : 8
Publication Date : 2014-09-10
Article Type : Other Papers
Abstract :Heart volume along with dose volume histograms are essential in reducing pulmonary and cardiac complications. The aim of this study is to measure the ventricular volume using computerized tomography insert ignore into journalissuearticles values(CT); and magnetic resonance imaging insert ignore into journalissuearticles values(MRI);, to detect the differences between the two scans and to investigate whether the estimated volumes concur with the actual volume of the hearts obtained by the fluid displacement technique. The present study were performed in six heart sheep. Hearts were scanned in the horizontal plane using CT insert ignore into journalissuearticles values(Toshiba, Aquilion, Japan); and MR machine insert ignore into journalissuearticles values(Siemens 1.5T Avanto, Germany);, we decided for 1 mm as sample thickness fraction for both MR and CT images.The images were analyzed using Image software. Planimetry and threshold stereological methods were applied to estimate the ventricular volume. To evaluate the accuracy of two scans, all the estimates were done by the same observer. The actual hearts mean volumes were 109.38 cm 3 ±17.77. The mean volume of the hearts in CT images of different thickness insert ignore into journalissuearticles values(0.94, 1.94, 2.94, 3.94 and 4.94 mm); were 110.34 cm 3 ±17.63, 110.61  cm 3 ±17.70, 111.03 cm 3 ±17.65, 111.48 cm 3 ±17.68 and 112.18 cm 3 ±17.86, respectively. The mean volume of the hearts in MRI of different thickness insert ignore into journalissuearticles values(1.1, 2.1, 3.1, 4.1 and 5.1 mm); were 103.78 cm 3 ±17.60, 104.12 cm 3 ±17.91, 104.31 cm 3 ±17.89, 104.41 cm 3 ±17.84 and 104.56 cm 3 ±17.95, respectively. There were significant statistical difference between the mean volume of the actual hearts and mean volume of the hearts in CT and MRI insert ignore into journalissuearticles values(p<0.05);. CT and MRI datasets allowed an interchangeable utilization of volumetric analysis tools, MRI demonstrated a significant reduction in the ventricular volume, while CT provides accurate volumetric information of the ventricles in comparison withactual hearts volume. However, reliable volumetric analysis was limited to an optimal range of cardiac rates for each modality.
Keywords : Computarized tomography image, magnetic resonance image, threshold, planimetry, ventricular volume

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.