  • Selcuk Dental Journal
  • Volume:4 Issue:1
  • Effect of luting space and cements on retention of implant supported crowns fabricated by laser sint...

Effect of luting space and cements on retention of implant supported crowns fabricated by laser sintering

Authors : Özgün Yusuf ÖZYILMAZ
Pages : 10-16
Doi:10.15311/1441.309573
View : 19 | Download : 11
Publication Date : 2017-04-28
Article Type : Research Paper
Abstract :Background: The aim of this study was to evaluate the retention strength of five different cements used for implant supported crowns with two cement gap values. Methods: Standard titanium abutments were scanned by means of a 3D digital laser scanner. 100 standard metal copings were designed by a CAD/CAM system with two cement gap values insert ignore into journalissuearticles values(20 and 40μm);. The copings were cemented to the abutments using the following five cements insert ignore into journalissuearticles values(n=10);. Poly F insert ignore into journalissuearticles values(PF);, GC FujiCEM insert ignore into journalissuearticles values(GCF);, Rely X insert ignore into journalissuearticles values(RX);, MIS Crown Setinsert ignore into journalissuearticles values(MCS); and Multilink N insert ignore into journalissuearticles values(MN);. The specimens were placed in 100% humudity for 24 hours then specimens were thermal cycled 1000 times. After thermal cycling specimens were subjected to a pull-out test using a universal testing machine at a 0.5 mm/min crosshead speed. The test results were analyzed with two-way ANOVA, followed by multiple comparisons using Tamhane tests insert ignore into journalissuearticles values(α=0.05);. Results: Statistical analysis revealed that significant differences were observed among cement groups insert ignore into journalissuearticles values(p<0.05);. PF and MN had the highest and the least mean retentive strength, respectively. No significant difference was found between RX and MCS. Increasing the cement gap from 20 to 40 μm improved retention significantly for each cement group insert ignore into journalissuearticles values(p<0.05);. Conclusion: The ranking of cements presented in the study is meant to be an arbitrary guide for the clinician in deciding the appropriate cement selection for CAD/CAM fabricated metal copings onto implant abutments.
Keywords : Cementation, cement gap, implant supported prosthesis, retention

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.