IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Selcuk Dental Journal
  • Volume:11 Issue:3
  • Comparison of the Effect of Adhesive Protocols and Light Curing Units on the Repair Bond Strength of...

Comparison of the Effect of Adhesive Protocols and Light Curing Units on the Repair Bond Strength of Bulk Fill Composite Resins

Authors : Kübra Bilge, İrem İpek, Enes Mustafa Aşar
Pages : 299-302
Doi:10.15311/selcukdentj.1512564
View : 30 | Download : 27
Publication Date : 2024-12-23
Article Type : Research Paper
Abstract :Background: The aim of this study is to compare the shear bond strength (SBS) after the repair of a microhybrid composite resin (CR) with three different bulk fill CRs using a 2nd and 3rd generation light-emitting diode (LED) light curing units and a universal adhesive with different application protocols. Methods: 120 acrylic blocks, each with an open surface and a depth of 2 mm and a diameter of 6 mm, were filled with a microhybrid CR (Filtek Z250) and cured with an LED for 20 seconds. The samples were roughened for 5 seconds with a diamond fissure bur under water cooling and then subjected to 5,000 thermal cycles. A universal adhesive was applied to the prepared samples using two different protocols (total etch and self-etch), and samples were then filled with bulk fill CRs. Each bulk fill CR group was polymerized with 2nd and 3rd generation LED to form subgroups (n=10). The SBS values were recorded in MPa using a universal testing device. Results: The highest SBS values were obtained for the X-tra Fil group in total etch mode with polymerization using 3rd generation LED, while the lowest SBS values were found for Filtek One Bulk Fill group in self-etch mode with polymerization using the 3rd generation LED. In all groups, total etch mode yielded higher SBS values compared to self-etch mode. Conclusion: Different adhesive protocols and LCUs were found to affect the SBS values of bulk fill CRs during repair.
Keywords : Adeziv Protokol, Bulk Fill Kompozitler, Kompozit Tamiri, LED Işık Cihazı

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025