  • Establishing reference values and evaluation of an in-house ferric reducing antioxidant power (FRAP)...

Establishing reference values and evaluation of an in-house ferric reducing antioxidant power (FRAP) colorimetric assay in microplates

Authors : Yasemin USTUNDAG, Kagan HUYSAL, Serdar KAHVECİOGLU, Hakan DEMİRCİ, Senol YAVUZ, Murat SAMBEL, Dursun UNAL
Pages : 126-131
Doi:10.18621/eurj.2016.5000190265
View : 26 | Download : 11
Publication Date : 2016-07-04
Article Type : Research Paper
Abstract :Objective.  The total antioxidant capacity insert ignore into journalissuearticles values(TAC); of a sample can be measured with a ferric reducing antioxidant power insert ignore into journalissuearticles values(FRAP); assay. There are commercially available kits for FRAP assays, however they are more expensive than in-house kits. We aimed to evaluate a FRAP direct measurement method under our laboratory conditions using a microplate reader and establish reference values to use in future research projects.  Methods.  An in-house microplate adaptation of the FRAP method was evaluated. Reference values of FRAP were established for one hundred and twenty subjects aged between 25-55 years. FRAP levels were estimated in 30 serum samples with high glucose concentration, 44 hyperbiluribinemic neonatals and 16 patients receiving renal replacement therapy insert ignore into journalissuearticles values(RRT);.  Results.  The mean FRAP level was 890±235 µmol/L. The median TAC level was 904 µmol/L. This method was found to be linear up to at least 2000 µmol/L. The intra- and inter-assay coefficients of variation were 2.7-6.7% and 5.3-10.1%, respectively. The mean FRAP level was lower than normal in diabetes and RRT patients and higher in hyperbiluribinemic neonatals insert ignore into journalissuearticles values(687±209 µmol/L, 609±250 µmol/L and 945±187 µmol/L, respectively);.  Conclusions.  Our reference values give comparable results with the literature. This method is simple, reliable, and inexpensive. It could be used for studies of oxidative stress-related diseases.
Keywords : Total antioxidant capacity, ferric reducing antioxidant power assay, evaluation, reference range, microplate

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.