Wrongs known as right in thyroid scintigraphy and uptake study

Authors : Serdar Savaş Gül
Pages : 142-147
Doi:10.18621/eurj.410060
View : 21 | Download : 29
Publication Date : 2019-01-04
Article Type : Research Paper
Abstract :Objectives: Thyroid scintigraphy using 99m Tc -pertechnetate is commonly used to study function and structure of thyroid gland. Pin-hole collimator is generally preferred in thyroid scintigraphy and uptake studies . The purpose of the present study was to determine actual radiopharmaceutical uptake value in an experimental 99m Tc-pertechnetate thyroid scintigraphy and uptake model. Methods: Thyroid hyperactive and hypoactive nodule models were created using 4 mCi insert ignore into journalissuearticles values(148 MBq); 99m Tc-pertechnetate. In the experimental model, 4 mm, 6 mm and 8 mm diameter pin-hole collimators, and 5 cm, 7 cm and 10 cm object-to-pinhole distances were investigated. Results: In thyroid hyperactive nodule model, despite the same activity value, uptake at 7 cm object-to-pinhole distance was higher compared to 10 cm distance insert ignore into journalissuearticles values(122% and 103%, respectively);. In the patient with Graves’ disease, despite the same activity value, uptake at 5 cm object-to-pinhole distance was higher compared to 10 cm distance insert ignore into journalissuearticles values(8% and 4%, respectively);. In thyroid hypoactive nodule model, 4 mm, 6 mm and 8 mm diameters pin-hole collimators were imaged at 5 cm, 10 cm and 15 cm object-to-pinhole distances . The resolution differences between the images were evaluated. Conclusion: It was determined that imaging using 10 cm object-to-pinhole distance and 4 mm diameter pin-hole collimator was best in terms of image resolution and optimum 99m Tc-pertechnetate uptake level. 
Keywords : 99mTc pertechnetate, thyroid, scintigraphy, uptake

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025