IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • The European Research Journal
  • Volume:6 Issue:3
  • Efficacy and feasibility of 226 Hz and 1000 Hz tympanometry in healthy pediatric patients

Efficacy and feasibility of 226 Hz and 1000 Hz tympanometry in healthy pediatric patients

Authors : Osman İlkay ÖZDAMAR, Gül ÖZBİLEN ACAR, Emel PEKTAŞ, Özlem ERTUĞRUL, Şayan YİĞİT
Pages : 200-203
Doi:10.18621/eurj.488170
View : 22 | Download : 10
Publication Date : 2020-05-04
Article Type : Research Paper
Abstract :Objectives: Tympanometric evaluation of middle ear with 226 Hertz insert ignore into journalissuearticles values(Hz); frequency probe has been widely used in patients with suspected middle ear and Eustachian tube disorders.   However most of the recent studies were demonstrated that tympanometric examination with 1000 Hz frequency probe was superior to 226 Hz frequency probe examination to detect middle ear disorders affecting middle ear admittance especially for infants. The objectiveinsert ignore into journalissuearticles values(s); of this study was to compare the reliability and feasibility of 226 Hz and 1000 Hz tympanometric results in normal hearing healthy pediatric group of patients. Methods: In this study, we evaluated normal healthy pediatric patients with 226 and 1000 Hz frequency probe tympanometry for the aim of comparing efficacy and detecting the rate of false negative tympanometric findings in these subjects. Forty-nine insert ignore into journalissuearticles values(98 ears); healthy pediatric patients insert ignore into journalissuearticles values(25 males and 24 females); were enrolled in the study and all of the patients were younger than 18 years of age. Oto-microscopic examination was performed to all of the patients as a gold standard. Results: The mean age was 9.3 ± 4.46 years old with a range from 3 to 17 years. The mean values of 226 Hz tympanometric measurement of right ears for ear volume, compliance, pressure and gradient were 74 ± 28.10, 59 ± 38.96, -46 ± 92.38 and 36 ±3 3.22, respectively; these values for the left ears were 84 ± 65.94, 51 ± 31.00, -57 ± 102.05 and 30 ± 23.35, respectively. The mean values of 1000 Hz tympanometric measurement of right ears for ear volume, compliance and pressure were 78 ± 23.03, 172 ± 85.04 and -22 ± 110.70, respectively; these values for the left ears were 64 ± 32.05, 147 ± 104.70, and 0 ± 98.20, respectively. Conclusions: We found that there was no superiority of the usage of 1000 Hz tympanometry to 226 Hz tympanometry in normal hearing healthy pediatric patients who were equal or older than 3 years of age.
Keywords : 1000 Hz tympanometry, 226 Hz tympanometry, children, normal hearing

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025