IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • The European Research Journal
  • Volume:6 Issue:6
  • Evaluation of myocardial function in pregnant women with speckle-tracking echocardiography

Evaluation of myocardial function in pregnant women with speckle-tracking echocardiography

Authors : Selma ARI, Hasan ARİ, Mustafa YILMAZ, Tahsin BOZAT
Pages : 615-623
Doi:10.18621/eurj.771627
View : 21 | Download : 14
Publication Date : 2020-11-04
Article Type : Research Paper
Abstract :Objectives: The speckle-tracking technique calculates the regional rate, the strain and the strain rate from two-dimensional gray-scale visualizations. The aim of this study was to evaluate with speckle-tracking echocardiography the effects of the first, second and third trimesters of pregnancy on cardiac functions. Methods: One hundred five voluntary pregnant and 35 healthy women of reproductive age were included in the study. For echocardiographic evaluations, the 111 highest-quality visualizations were chosen: 24 cases in the first trimester, 31 cases in the second trimester, 32 cases in the third trimester and 24 healthy women as a control group. Global longitudinal, radial, and circumferential strain, and left ventricular insert ignore into journalissuearticles values(LV); rotation and twist were evaluated by two-dimensional speckle tracking echocardiography. Results: During pregnancy, the diameter, and volume of the left atrium, LV stroke volume, and the heart rate significantly increased beginning in the first trimester insert ignore into journalissuearticles values( p < 0.0125);. The parameters of pulse-Doppler E velocity and tissue Doppler Em velocity significantly increased in the first trimester insert ignore into journalissuearticles values( p < 0.0125);, whereas in the second and third trimester they decreased to control levels. Global longitudinal strain was significantly decreased in the third trimester of the pregnancy insert ignore into journalissuearticles values( p < 0.0125);. Basal and apical LV rotation and twist were significantly increased in the third trimester of pregnancy insert ignore into journalissuearticles values( p < 0.0125);. LV apical and basal reverse rotation rate were significantly increased in the first trimester of pregnancy insert ignore into journalissuearticles values( p < 0.0125);. Conclusions: In the third trimester global longitudinal strain decreased whereas LV rotation and twist increased. Speckle-tracking echocardiography may be used to evaluate the effects of pregnancy and that provide further data on cardiac functions. 
Keywords : Strain, echocardiography, tissue Doppler imaging, pregnancy

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025