Effect of Thermal Screens on the Microclimate and Overall Heat Loss Coefficient in Plastic Tunnel Greenhouses

Authors : H Hüseyin ÖZTÜRK, Ali BAŞÇETİNÇELİK
Pages : 123-134
View : 19 | Download : 10
Publication Date : 2003-06-01
Article Type : Research Paper
Abstract :The objective of the present study was to evaluate the effects of thermal screens made of clear polyethylene insert ignore into journalissuearticles values(PE); and polyester material on the microclimate and overall heat loss coefficient in plastic tunnel greenhouses. The dimensions of the plastic tunnels were: width 6 m, length 20 m and height 3 m. Three different installations were used: insert ignore into journalissuearticles values(1); a single cover without a screen insert ignore into journalissuearticles values(as a control);; insert ignore into journalissuearticles values(2); a single cover with a PE screen; and insert ignore into journalissuearticles values(3); a single cover with a polyester screen. The thermal screens made of PE with UV+IR additives and polyester materials were placed at a height of 2.5 m in the plastic tunnels, and supported with wires. Air temperature, relative humidity, wind speed, solar radiation and photosynthetically active radiation insert ignore into journalissuearticles values(PAR); were measured and recorded on a data-logger. In the plastic tunnels, the overall heat loss coefficient, heat input, the control factor for air-tightness, the rate of heat loss and the thermal screen effectiveness were calculated. The results showed that the polyester and PE screens were able to keep the air temperature inside the plastic tunnels 4.8 °C and 2.5 °C higher than that outside, respectively. Comparison of the calculated overall heat loss coefficients shows that the differences in the values between the plastic tunnels were large. The relationships between the overall heat loss coefficient and the wind speed, and the outside temperature were modeled, including the measured and calculated values. It was found that the thermal screen effectiveness was 16% and 19.8% for the PE and polyester screens, respectively.
Keywords : Plastic tunnel, Thermal screen, Overall heat loss coefficient

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.