IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Chemistry
  • Volume:34 Issue:6
  • Nile Blue-hexacyanoferrate carbon paste modified electrode as an amperometric sensor for determinati...

Nile Blue-hexacyanoferrate carbon paste modified electrode as an amperometric sensor for determination of hydrazine

Authors : Reza Emamali SABZI, Elnaz MINAIE, Khalil FARHADI, Mir Maqsoud GOLZAN
Pages : 901-910
View : 17 | Download : 6
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :The main problem associated with metal hexacyanoferrates insert ignore into journalissuearticles values(MHCFs); is their instability at high pH values. We synthesized a new Prussian Blue analogue, Nile-Blue hexacyanoferrate insert ignore into journalissuearticles values(NBHCF);, that remains stable in 0.2 M KOH. A carbon paste insert ignore into journalissuearticles values(CPE); chemically modified electrode insert ignore into journalissuearticles values(ME); containing NBHCF was prepared as a stable electrochemical sensor for measuring hydrazine. A detailed characterization of the electrochemical and electrocatalytic behavior of NBHCF was performed using cyclic voltammetric, chronoamperometric, differential pulse voltammetric insert ignore into journalissuearticles values(DPV); and hydrodynamic amperometric methods. The NBHCF-modified electrode produced reproducible redox peaks and resulted in a linear increase in the oxidation signal of hydrazine with increasing concentration of hydrazine in the range of 0.1-6.0 mM insert ignore into journalissuearticles values(in hydrodynamic amperometry method insert ignore into journalissuearticles values(HDA););. The electrode detection limit was 40 m M and possessed a surface coverage of G = 2.0 \times 10-8 mol cm-2.
Keywords : Modified electrode, carbon paste electrode, hexacyanoferrate, amperometric determination of hydrazine, Nile Blue hexacyanoferrate

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025