IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Chemistry
  • Volume:31 Issue:4
  • N,N`-Bis(1`-hydroxy-2`-acetonaphthone)propylenediamine: Synthesis, Extractive Properties, and Use as...

N,N`-Bis(1`-hydroxy-2`-acetonaphthone)propylenediamine: Synthesis, Extractive Properties, and Use as an Ionophore in a Cu(II)-Selective Potentiometric Sensor

Authors : Daryoush EMADI, Mohammad Reza YAFTIAN and Saeed RAYATI
Pages : 423-433
View : 15 | Download : 8
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :The binding ability of N,N`-bisinsert ignore into journalissuearticles values(1`-hydroxy-2`-acetonaphthone);propylenediimine insert ignore into journalissuearticles values(H2L); towards metal ions was investigated by performing liquid-liquid extraction experiments to extract Cu2+, Ni2+, Co2+, and Zn2+ ions from nitrate solutions. Extraction takes place by a cation exchange mechanism and the ligand shows a pronounced selectivity towards Cu2+ ions. Conventional log-log analysis of the extraction data reveals that the Cu2+ ions are extracted by a 1:1 insert ignore into journalissuearticles values(metal to ligand); complex formation. The effect of parameters influencing the extraction process, such as type of diluent and concentration of electrolyte in the aqueous phase, has been studied. The selectivity of the ligand was evaluated by competitive extraction of copper ions from a synthetic sample. The selective extraction of copper ions allows the use of H2L as an ion-sensing material for fabricating a Cuinsert ignore into journalissuearticles values(II);-ion-selective electrode. This sensor gave a good Nernstian response of 29.7 \pm 0.3 mV/decade over a concentration range of 10-4-10-1 M of copper ions, independent of pH in the range of 3.5-6.5, with a detection limit of 2 \times 10-5 M and a response time of < 20 s. The electrode was used as a potentiometric indicator for the complexometric titration of a copper solution with a standard solution of EDTA
Keywords : Turk J Chem, 31, 2007, 423 433 Turk J Chem, vol 31, iss 4

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025